Over air configuration authentication
Configure module according to 6.4 command table.
7.2 Data transmission
For data transmission related instructions, see 5.3 Data Transmission Mode.
Test Conditions:
Configure one module as the master and one as the slave as described in the quick use guide for AT command
list configuration mode;
Software: XCOM.
Other parameters are the default configuration.
7.2.1 Data transparent transmission
1. Power on the module. Enable logmsg printing both for master and slave (at+logmsg=1);
2. Set both master and slave module as transparent transmission mode (AT+TRANMD=1).
3. After the master successfully connecting, it will print "sta: connecte 0 616263646564"; the slave will print sta: connecte 0
616263646566". The LINK pin is high. As shown in below figure, the master is automatically connected and printed; The slave is
powered on and automatically print. The value before the MAC address in the information printed by the master is the slave handle in
the master, and the first byte of the format transmission comes from this.