CC1310 Wireless Module
E70 Series User Manual
Copyright ©2012–2017, Chengdu Ebyte Electronic Technology Co., Ltd.
26
/
34
2
1
0
Air data rate(bps)
The lower the air data rate, the longer the transmitting
distance, better anti-interference performance and longer
transmitting time
The air data rate must keep the same for both
communication parties.
0
0
0
2.5kbps
0
0
1
5kbps
0
1
0
12kbps(Default)
0
1
1
28kbps
1
0
0
64kbps
1
0
1
168kbps
1
1
0
168kbps
1
1
1
168kbps
4
CHAN
7
6
5
Packet length (only for subpackage mode)
Under continuous transmitting mode (M0=1 M1=0
M2=0), this parameter is invalid
0
0
0
16 bytes
0
0
1
32 bytes
0
1
0
64 bytes(Default)
0
1
1
128 bytes
1
0
0
256 bytes
1
0
1
512 bytes
1
1
0
1024 bytes
1
1
1
2048 bytes
Communication Channel
00H~1FH, 431~446.5MHz,(Default)04H(433M)
Model: E70 (433T14S2)/ E70 (433T14S)/ E70 (433T30S)
00H~1FH, 861~876.5MHz,(Default)0EH(868M)
Model: E70 (868T14S2)/ E70 (868T14S)/ E70 (868T30S)
00H~1FH, 907~922.5MHz,(Default)10H(915M)
Model: E70 (915T14S2)/ E70 (915T14S)/ E70 (915T30S)
5
OPTION
7
Fixed transmission (similar to MODBUS)
When it is 1, the first three bytes of each user data frame
can be used as high/low address and channel. The
module changes its address and channel when
transmitting. And it will revert to original setting after the
process is completed.
It is transparent transmission under continuous mode.
0
Transparent transmission mode (Default)
1
Fixed transmission mode
6
5
4
wireless wake-up time
This parameter is only valid for mode 4, 6.
For mode 6, the wake-up time will affect the WOR cycle
of the module, and affect the power consumption.
For mode 4, the wake-up time decides the number of
wake-up code before transmission so as to ensure the
wake up the module in mode 6.
Generally, mode 4 and 6 shall be used jointly and the
wake-up time on both modules shall be the same.
0
0
0
500ms
0
0
1
1000ms(Default)
0
1
0
1500ms
0
1
1
2000ms
1
0
0
2500ms
1
0
1
3000ms
1
1
0
3500ms
1
1
1
4000ms
3
FEC switch
After turn off FEC, the actual data transmission rate
increases while anti-interference ability decreases. Also,
the transmission distance is relatively short.
Both communication parties must keep on the same
pages about turn-on or turn-off FEC.
0
Turn off FEC
1
Turn on FEC (Default))
2
IO drive mode
This bit is used to the internal pull-up resistor. It also
increases the level’s adaptability in case of open drain. But
0
TXD and AUX push-pull outputs, RXD pull-up inputs