Chengdu Ebyte Electronic Technology Co.,Ltd. E62-DTU (433D20) user manual
Copyright ©2012–2019
,
Chengdu Ebyte Electronic Technology Co,;Ltd 9
5.3.
Frequency range and channels
Model
Default frequency
Frequency range
Channel
spacing
Channels
Hz
Hz
Hz
E62-DTU (433D20)
433
425 ~ 450.5
0.1
Full-duplex
★
Note: In the same a rea when mu ltip le data transceivers are commun icating one to one at the same time, it is
recommended to set the channel spacing between each group of data transceivers at 2MHz or more.
5.4.
Transmit power level
Model
15mW
25mW
50mW
100mW
E62-DTU (433D20)
√
√
√
√
★
Note: The lowe r the transmit power, the c loser the transmission distance, but the working current won’t be declined in
exact proportion, it is recommended to use the maximu m transmit power.
5.5.
Current parameters
Model
Transmitting current mA
Standby current mA
12V
24V
12V
24V
E62-DTU (433D20)
104
66
40
36
★
Note: It is recommended to retain more than 50% o f the current marg in when selecting the power supply, which will
help the data transceiver to work steadily for a long time.
5.6.
Transceiver Length and Sub-packing Mode
Model
Buffer
Sub-package
E62-DTU (433D20)
2048Byte
Large buffer
★
Note:
1. When the receiving data is more than a single packet capacity, the beyond part will be automat ically assigned
to the second transmission until it is completed;
2. The data transceiver cannot receive data which is more than the buffer capacity;
Содержание 433D20