background image

Chengdu Ebyte Electronic Technology Co,;Ltd

E90-DTU (400SL22-GPRS) user manual

Copyright ©2012–2019,Chengdu Ebyte Electronic Technology Co,;Ltd

14

2.2 Working mode and functions

1

Working modes are divided into communication mode and configuration mode, which are subdivided into GPRS/2G
network pass-through configuration mode and RF configuration mode.

( a ) Communication mode: the radio works in the communication mode by default after power on, and
automatically starts the network connection. When the connection is established with the server, any data received by
the radio will be transmitted to the server. At the same time, it can also receive data from the server. After receiving
the data from the server, the module will output directly through the rf module. This module supports a maximum
length of 512 bytes per packet.

( b ) GPRS/2G network pass-through configuration mode: in this mode, the user can configure radio GPRS/2G
network pass-through parameters.

( c ) RF configuration mode: this mode allows users to configure radio RF parameters.

( d ) Mode switch: use the official E90-DTU (230SL30-GPRS) to configure the upper computer for mode switch and
parameter configuration. Note that after using the upper computer to enter the configuration state, the system is in
the configuration mode. At this time, click the "module restart" button or "enter the communication button", and the
system will switch to the communication mode. After entering the configuration state, unplug the USB cable and the
system will automatically switch to the communication mode. At this time, if the parameters are not saved in
advance or the GPRS/2G network transmission parameters are modified but the "module restart" button is not
clicked, the modified parameters will not take effect.

2

Base station positioning function;

E90-DTU (400SL22-GPRS) supports the base station positioning function. Users can use the officially

provided E90-DTU (400SL22-GPRS) configuration software and click the "query LBS information" button in the
GPRS/2G network transmission configuration mode to read the LBS information of the device in the current period.

Содержание 400SL22-GPRS

Страница 1: ...E90 DTU 400SL22 GPRS...

Страница 2: ...byte Electronic Technology Co Ltd 1 Content 1 OVERVIEW 2 1 1 INTRODUCTION 2 1 2 FEATURES 3 1 3 STATION SYSTEM PARAMETERS 4 1 4 PIN DESCRIPTION 5 1 5 SIZE 7 2 QUICK START 8 2 1 HARDWARE PREPARATION AND...

Страница 3: ...e to have a variety of transmission modes At the network end of GPRS network the radio supports LTE FDD TTE TDD WCDMA TD SCDMA CDMA GSM wireless communication data transmission and supports LTE FDD LT...

Страница 4: ...frequency The measured communication distance of RF can reach 5km Support global license free ISM 433mhz including 470mhz for metering reading Support data transmission rate of 0 3kbps 62 5kbps Based...

Страница 5: ...USSD The antenna interface SMA interface NET signal output 50ohm characteristic impedance Transmission Power Class 4 2W GSM850 and EGSM900 Class 1 1W DCS1800 and PCS1900 RF Characteristic parameters...

Страница 6: ...manual Copyright 2012 2019 Chengdu Ebyte Electronic Technology Co Ltd 5 1 4 Pin Description 3GPP Frequency 1 Timeslot 2 Timeslot 4 Timeslot CS 1 9 05kbps 18 1kbps 36 2kbps CS 2 13 4kbps 26 8kbps 53 6...

Страница 7: ...on long press time no requirement 6 USB Micro USB parameter configuration interface 7 Reload Press 4 10s to restore the factory Settings 8 PWR Red power indicator 9 WORK Yellow data transmission indic...

Страница 8: ...Chengdu Ebyte Electronic Technology Co Ltd E90 DTU 400SL22 GPRS user manual Copyright 2012 2019 Chengdu Ebyte Electronic Technology Co Ltd 7 1 5 Size...

Страница 9: ...22 GPRS device and E22 400TXXS module 5V 20V Power adapter USB switch to TTL module and USB wire GPRS LTE Sucker antenna Computer browser visit Chengdu Ebyte official website www ebyte com download th...

Страница 10: ...rrectly connected the message box on the right side will prompt device ready 3 After entering the GPRS 2G network pass through configuration mode the parameters of GPRS 2G module can be configured in...

Страница 11: ...the RF module in the setting of relevant parameters After the configuration is completed click the save RF parameters button After completion as shown in the following figure 5 After the configuratio...

Страница 12: ...e restart button and directly click the enter communication state button in the RF mode After completion as shown in the following figure 6 Within 30 seconds after the communication state is entered i...

Страница 13: ...Copyright 2012 2019 Chengdu Ebyte Electronic Technology Co Ltd 12 8 Use the serial port assistant to send data to E22 400TXXS module If E90 DTU 400SL22 GPRS receives the data sent by E22 400TXXS the W...

Страница 14: ...Chengdu Ebyte Electronic Technology Co Ltd E90 DTU 400SL22 GPRS user manual Copyright 2012 2019 Chengdu Ebyte Electronic Technology Co Ltd 13 b E90 DTU 400SL22 GPRS sends data to E22 400TXXS...

Страница 15: ...meters c RF configuration mode this mode allows users to configure radio RF parameters d Mode switch use the official E90 DTU 230SL30 GPRS to configure the upper computer for mode switch and parameter...

Страница 16: ...th the server you can choose whether to clear the cached data By default clearing the cache will be closed The maximum packet length from the local cache is 256 bytes 7 The cloud transmission function...

Страница 17: ...nel of module B then module B can receive AA BB CC and other modules do not receive data the same is true for E90 DTU xxx SLXX series stations 6 LoRa spread spectrum LoRa direct sequence spread spectr...

Страница 18: ...chnology Co Ltd E90 DTU 400SL22 GPRS user manual Copyright 2012 2019 Chengdu Ebyte Electronic Technology Co Ltd 17 3 Application model 1 E22 400TXXS E90 DTU 400SL22 GPRS Server A 2 E90 DTU 400SLxx E90...

Страница 19: ...Chengdu Ebyte Electronic Technology Co Ltd E90 DTU 400SL22 GPRS user manual Copyright 2012 2019 Chengdu Ebyte Electronic Technology Co Ltd 18 3 Ebyte cloud transmission 4 Application in buildings...

Страница 20: ...rectly If they are connected try to press the Reset button re plug the power cord or re plug the USB Server A of this product is always open After successful initialization it will automatically estab...