Chengdu Ebyte Electronic Technology Co., Ltd.
E90-DTU(2G4L27)User Manual
Copyright ©2012–2020
,
Chengdu Ebyte Electronic Technology Co., Ltd.
13
5.4 Current parameter
Model No.
Average emission current mA
Waiting average current mA
12V
24V
12V
24V
E90-DTU(2G4L27)
226
110
22
15
★
Note: 12V transient transmission MAX current: 66mA, 24V transient transmission MAX current: 33mA, it is
recommended to reserve ≥50% MAX current margin when selecting the power supply, which is beneficial to the
long-term stable operation of the radio.