E90-DTU SL User Manual

Copyright2012–20231

ChengduEbyteElectronicTechnologyCo,;Ltd

16

03H

Read/Wri

te

REG0

7

6

5

UART baud rate

bps

000

baud rate is 1200

001

baud rate is 2400

010

baud rate is 4800

011

baud rate is 9600

Default

100

baud rate is 19200

101

baud rate is 38400

110

baud rate is 57600

111

baud rate is 115200

-----------------------------------------------

4

3

UART parity bit
00

8N1

Default

01

8O1

10

8E1

11

8N1

same as 00

-----------------------------------------------

2

1

0

air data rate

000

air data rate is 2.4k

001

air data rate is 2.4k

010

air data rate is 2.4k

Default

011

air data rate is 2.4k

100

air data rate is 4.8k

101

air data rate is 9.6k

110

air data rate is 15.6k

111

air data rate is 15.6k

For the two modules that

communicate with each other, the

serial port baud rate can be

different, and the verification

method can also be different.

When transmitting large packets

continuously, users need to

consider the data blocking caused

by the same baud rate, and data

may even be lost. It is generally

recommended that both parties

have the same baud rate.

-------------------------------------

It should be the same for both

communication parities .

The higher the rate, the shorter the

distance.

04H

Read/Wri

te

REG1

7

6

sub-packing setting

00

240byte

Default

01

128byte

10

64byte

11

32byte

-----------------------------------------------

5

enable RSSI environmental noise

1

on

0

off

Default

-----------------------------------------------

4

3

2 remain

-----------------------------------------------

1

0

TX power

00

37dbm

Default

01

37dbm

10

37dbm

When the data is smaller than the

sub packet length, the serial output

of the receiving end is an

uninterrupted continuous output.

When the data is larger than the

sub packet length, the receiving

end serial port will output the sub

packet.

--------------------------------------

When enabled, the C0 C1 C2 C3

command can be sent in the

transmitting mode or WOR

transmitting mode to read the

register.

Register 0x00: Current ambient

noise rssi

Register 0X01: rssi when the data

was received last time.

Current channel noise is: dBm

=-RSSI/2

Command format: C0 C1 C2 C3 +

starting a read length

Returns: C1 + address a read

 read valid value

E.g: send C0 C1 C2 C3 00 01

Return C1 00 01 rssi

Содержание 230SL37

Страница 1: ...E90 DTU 230SL37 New LoRa long Distance High Power...

Страница 2: ...5 4 Air data rate 11 5 5 Current 11 5 6 TX and RX FIFO and sub packing method 11 6 Function Description 12 6 1 Fixed Transmission 12 6 3 Broadcast Address 12 6 4 Monitor Address 13 7 Operating mode 1...

Страница 3: ...cal fiber microwave and bright line it provides real time and reliable data transmission of monitoring signals in private networks under certain special conditions with low cost installation and maint...

Страница 4: ...ency stability is better than 1 5PPM Operating temperature range 40 C 85 C to adapt to a variety of harsh working environment All aluminum alloy casing compact size easy installation and good heat dis...

Страница 5: ...ct the baud rate 9600bps check mode as 8N1 to realize transparent transmission 4 If customer needs to modify the parameters please dial the switch in the configuration mode and connect to the computer...

Страница 6: ...Ebyte Electronic Technology Co Ltd E90 DTU SL User Manual Copyright2012 20231ChengduEbyteElectronicTechnologyCo Ltd 6 Mode 0 Factory default Mode 2 Parameter configuration 3 Dimensions 3 1 Parts desc...

Страница 7: ...ndard RS 485 interface and pressure line power interface 3 PWR LED Power LED Red lit when the power is on 4 TXD LED Transmit LED Yellow blinks when sending data 5 RXD LED Receive LED Yellow blinks whe...

Страница 8: ...Chengdu Ebyte Electronic Technology Co Ltd E90 DTU SL User Manual Copyright2012 20231ChengduEbyteElectronicTechnologyCo Ltd 8 unit mm...

Страница 9: ...4 2 RS232 The E90 DTU can be connected to the device via RS 232 using the standard DB 9 interface 4 3 RS485 E90 DTU can be connected to the 485_A terminal and 485_B terminal from with the RS 485 A ter...

Страница 10: ...long distance Note Test condition in clear and open air without shelters 12V 2A power supply 5dBi gain sucker antenna over 2 meters height from the ground with the factory default parameters 5 2 Gene...

Страница 11: ...the rate meets the requirements the lower air data rate the better quality 5 5 Current Model TX current mA Standby current mA 12V 24V 12V 24V E90 DTU 230SL37 1200 600 50 27 Note It is recommended to...

Страница 12: ...2 6 Function Description 6 1 Fixed Transmission 6 2 Broadcast Transmission 6 3 Broadcast Address For example Set the address of module A as 0xFFFF and channel as 0x04 When module A is the transmitter...

Страница 13: ...al mode mode 0 Categories M1 M0 Notes Mode 0 Normal Mode ON ON Open UART Comm port and RF transparent transmission is on configuration over air via special command is available Mode 1 Reserved mode ON...

Страница 14: ...gth parameter Reply C1 start address length parameter Example 1 set channel as 0x09 command start address length parameter Transmit C0 05 01 09 Return C1 05 01 09 Example 2 set module address 0x1234 n...

Страница 15: ...C0 05 01 09 Return CF CF C1 05 01 09 Example 2 set module address 0x1234 network address 0x00 UART 9600 8N1 air data rate 1 2K Transmit CF CF C0 00 04 12 34 00 61 Return CF CF C1 00 04 12 34 00 61 6...

Страница 16: ...locking caused by the same baud rate and data may even be lost It is generally recommended that both parties have the same baud rate It should be the same for both communication parities The higher th...

Страница 17: ...1 2000ms Default 100 2500ms 101 3000ms When enabled the module receives wireless data and it will follow an RSSI strength byte after output via the serial port TXD The module recognizes the first thre...

Страница 18: ...Factory default parameter Default parameter 0x00 0x00 0x00 0x63 0x00 0x28 0x03 0x00 0x00 Model NO Frequency Address Channel Air data rate Baud rate Parity bit TX power E90 DTU 230SL37 230 125MHz 0x000...

Страница 19: ...ary repeater s ADDH ADDL are 33 05 Therefore Repeater 2 can forward the data of Repeater 1 to the network NETID 05 Thus node 3 and node 4 can receive node 1 data Node 4 outputs data normally and node...

Страница 20: ...onfigures the repeater mode using the host computer special attention must be paid Since the parameters are in decimal mode in the host computer the module address and network ID need to be converted...

Страница 21: ...ion diagram Operating mode M1 M0 Note Configuration mode OFF ON Programming via the configuration software is available only in this mode 1 Programming can only be performed in a specific operating mo...

Страница 22: ...2 RS232 RS485 433 470M 22 5 LoRa wireless configuration networking transmission long distance anti inference E90 DTU 400SL30 RS232 RS485 433 470M 30 10 LoRa wireless configuration networking transmiss...

Страница 23: ...arrow band for complex environment strong diffraction ability Note Interoperable with E22 400T22S E22 400T30S E90 DTU 400SL22 E90 DTU 400SL30 products 14 Application field The data transceiver of CDEB...

Страница 24: ...When testing the data transceiver it must be connected with a matching antenna or a 50 dummy load otherwise it will easily damage the transmitter if the antenna is connected the distance of the human...

Страница 25: ...20 04 20 Content revision du 1 3 2021 1 27 Content revision ly 1 4 2021 10 09 Content revision xxl 1 5 2023 08 29 Content revision Bin About us Technical support support cdebyte com Documents and RF S...

Отзывы: