Ebsray Z Series Скачать руководство пользователя страница 3

 

SECTION 1 – GENERAL 

 

INTRODUCTION 

This publication is intended to assist those involved with 
the installation, operation and maintenance of EBSRAY 
Models ZB120 and Z580 Internal Gear pumps. The design, 
materials and workmanship incorporated in the 
manufacture of EBSRAY pumps make them capable of 
reliable operation over a long working life.  Correct 
installation is essential.  Service life is enhanced by 
periodic inspection and careful maintenance. 
 
 

1.1 CAUTION 

INSTALLATION AND SERVICING OF THIS EQUIPMENT 
SHOULD BE PERFORMED BY QUALIFIED COMPETENT 
PERSONNEL IN ACCORDANCE WITH RELEVANT 
STATUTORY REGULATIONS OR CODES, IN 
CONJUNCTION WITH THESE INSTRUCTIONS. 
 
 
When the equipment supplied utilises components other 
than manufactured by EBSRAY e.g. couplings, speed 
reducers, electric motors etc, reference should be made to 
the original manufacturer’s data before installation or 
servicing is commenced.  Failure to observe these details 
may void the warranty. 
 
 

1.2 WARNING

 

The pump must be operated within the original selected 
design parameters of speed, temperature, pressure and 
viscosity.  Should any change be contemplated, please 
confer with EBSRAY in order to verify the suitability of such 
a change. 

1.3 TRANSPORTATION AND PACKING

 

Standard domestic packing is suitable for shipment in 
covered transports.  Ports must be sealed to exclude 
ingress of solids.  When received on site the pump should 
be stored in a dry covered area. 
 
If storage is required for other than a short period prior to 
installation, special preservatives and protective wrappings 
will be required. 
 
 

1.4 INSPECTION ON RECEIPT – SHORTAGES

 

On receipt of equipment, check all items against the 
dispatch documents and inspect for damage.  Any damage 
or shortage incurred during transit should be noted on the 
packing note and on both your own and the carrier’s copy 
of the consignment note and a claim should be made 
immediately on the transport company. 
 
Should a shortage be evident on receipt, notify EBSRAY 
immediately giving full details and packing note number. 
 
 

1.5 HANDLING

 

Care should be used in moving pumps. Do not drop pumps 
and do not expose pumps to excessive heat or corrosive 
materials. Baseplate mounted units should be lifted from 
under the baseplate below both the pump and driver 
ensuring compliance with the relevant lifting codes.

 
 
 
 
 
 

DETERMINATION OF MAINTENANCE REQUIREMENTS 

 

EBSRAY Z Series Pumps are used for a wide range of applications and as such, maintenance requirements will vary between 
applications. Under ideal/good operating conditions, providing pump is not run dry, internal inspection is generally not required 
unless either performance drops off or unusual noises, vibrations or leaks occur. During inspection, check bearings and other 
components for wear or damage. 
Any reduction in performance (either flow, differential pressure or efficiency) will indicate either a system, Pumpset or pump 
anomaly. Regular observation during operation will quickly identify symptoms such as leaking seals. Development of unusual 
noises or vibration may indicate system/hydraulic problems, excessive wear, mechanical damage or foreign objects I the pump

 

Содержание Z Series

Страница 1: ...Publication 2190 06 EBSRAY PUMPS INSTALLATION OPERATION MAINTENANCE INSTRUCTIONS Z SERIES MODELS ZB120 Z580...

Страница 2: ...STARTUP CHECKLIST 5 3 5 OPERATIONAL CHECKS 5 SECTION 4 MAINTENANCE 5 4 1 SPARE PARTS 5 4 2 PREPARATION FOR DISASSEMBLY 5 4 3 DISASSEMBLY 6 4 4 INSPECTION 6 4 5 REASSEMBLY PRELIMINARY 6 4 6 REASSEMBLY...

Страница 3: ...a short period prior to installation special preservatives and protective wrappings will be required 1 4 INSPECTION ON RECEIPT SHORTAGES On receipt of equipment check all items against the dispatch d...

Страница 4: ...ittings are not over tightened Over tightening tapered connections may cause body to fracture 2 4 STRAINER PROTECTION The pump suction should always be protected by an efficient suction strainer of ad...

Страница 5: ...ch employ costly external timing gears to minimize tooth wear The Inner Rotor B remains in almost hydraulic balance requiring only minimal torsional load to effectively follow the Outer Rotor A 3 3 LU...

Страница 6: ...rs allow 4 5 REASSEMBLY PRELIMINARY 1 Ensure all parts are clean and free from burrs etc Do not round off sharp edges of rotors as this may affect performance 2 Lightly smear all O Rings and lapped fa...

Страница 7: ...FT 1 9 SPRING WASHER Cover 6 48 VALVE 1 17 GLAND Packed 1 53 SPRING Bypass 1 20 GLAND NUT 1 54 LOCKNUT Bypass 1 21 PACKING SET 1 Set 55 ADJUSTING SCREW 1 22 SEAL FACE 1 56 ADJUSTING CAP 1 23 SEAL SEAT...

Страница 8: ...R CONSUMPTION 1 Differential pressure head higher than rating check for obstruction 2 Liquid properties not as specified check specific gravity and viscosity 3 Rotating parts binding 4 Misalignment be...

Отзывы: