EBS HandJet  250 Скачать руководство пользователя страница 19

 

20111028#4.2

 

EBS Ink-Jet Systeme

 

EN

  

 

19

 

EN

NOTE: An increment (decrement) is added to the 
counter each time button 

5

 is pressed and the 

contents of the incremental (decremental) 
counter increases (decreases). The only excep-
tion is when a text is to be printed repeatedly, 
that is when the print parameter 

Text repeti-

tions

>

1

  or  is  set  to 

Continuous

. In such a 

situation button 

5

 does not time each of the 

prints but rather groups of prints. The 

Refresh 

var.fields

 parameter from the 

Parameters 3

 tab 

decides whether every successive repetitive print 
modifies the contents of the counters or not. The 
distance between the beginnings of two con-
secutive prints produced with repetitive printing 
is defined with the 

Rep. distance

 parameter 

from the 

Parameters 2

 tab. 

Example

: For the counter defined as above set 

the 

Text repetitions

 parameter to 

3

a). If the 

Refresh var.fields

 parameter is set to 

OFF, the following prints can be produced: 

If release button 

5

 

is pressed for xth 
time 

The following counter 
contents are printed: 

0000 0000 0000 

0001 0001 0001 

0002 0002 0002 

--- 

--- --- --- 

999 

0999 0999 0999 

b). If the 

Refresh var.fields

 parameter is set to 

ON, the following prints can be produced: 

If release button 

5

 

is pressed for xth 
time 

The following counter 
contents are printed: 

0000 0001 0002 

0003 0004 0005 

0006 0007 0008 

0009 0010 0011 

--- 

--- --- --- 

333 

0996 0997 0998 

334 

0999 1000 1001 

Database Data 

The contents of the database can be 
printed automatically on every suc-
cessive object to be labelled owing to 
the 

database

 variable field. 

!

 

The database handling option is 
available for the EBS250C printers 
after an enable code has been typed 
in. Contact your printer distributor to 
obtain the code. After the code has 
been input, the enable setting is 
saved permanently in printer mem-
ory. 

The database (also in the form of 
Excel and text files) can be accessed 
via an ODBC software interface. 

In order to insert a database variable 
field, follow the steps given below: 
1.  In the text edit line position the 

cursor in the place where you 
want the data to be displayed. 

2.  While holding the cursor on the 

text edit line, press the right 
mouse button (or the MENU but-
ton) and select the 

Define vari-

able field

 command from the 

menu displayed. Then select 

Insert Database

 from the list 

displayed. You can also do that 

using the 

 key on the tool bar 

of the text edit window. 

In the window displayed, configure a 
link to the database: 
1. Press 

the 

Connection settings

 

key and then choose 

Microsoft 

OLE DB Provider for ODBC Driv-
ers

 in the 

Provider

 tab of the 

Data Link Properties

 window and 

press the 

Next

 key. 

2. In the 

Specify the source data

 

item of the 

Connection

 tab 

choose 

Use connection string

 

and press the 

Build...

 key. 

3. In 

the 

Select Data Source

 win-

dow press the 

New...

 key to es-

tablish a link. 

!

 

If a given source is to be used again, 
it can be chosen from the list and 
steps 3 to 7 can be omitted. 

4. In 

the 

Create New Data Source

 

window choose a driver for han-
dling Excel files (*.xls) and press 
the 

Next

 key. 

5.  Type in the name of a new source 

of data and press the 

Next

 key. 

6.  Confirm whether the data source 

settings are correct by pressing 
the 

Finish

 key. 

7. In the 

ODBC Microsoft Excel 

Setup

 window indicate an *.xls 

Содержание HandJet 250

Страница 1: ...Operating Manual v 20111028 4 2 EN English...

Страница 2: ...2 EBS Ink Jet Systeme 20111028 4 2 A 1 2 8 4 5 3 10 7 6 11 13 14 15 12 F ON OFF PRINT POWER ERROR CHARGE 16 18 20 17 19 21 9 33 B 23 24 22 C 15 14 25 26...

Страница 3: ...20111028 4 2 EBS Ink Jet Systeme 3 D 27 22 28 24 PC USB 23 E 10 28 29 12 30 31...

Страница 4: ...r 29 Non return valves in the ink con tainer and ink system 30 Guide bayonets in the ink con tainer 31 Ink container gasket 32 Buzzer a buzzing signal generator located inside element 7 of the printer...

Страница 5: ...remental counter inserts Shift F2 green Variable field universal date and time inserts Shift F12 turquoise Editing markers Wraparound marker green A marker white in colour means that the cursor is jus...

Страница 6: ...AM 13 CONNECTING THE PRINTER WITH COMPUTER 13 TEXT FILES AND PRINT PARAMETERS 14 HOW TO CREATE A TEXT TO BE PRINTED 14 REGULAR TEXT 14 Changing Proportional Spacing and Monospacing 14 Using and Changi...

Страница 7: ...torial and printing errors in this manual If your device contains a particular piece of equipment or needs performing an operation that have not been illustrated or described in this manual or if you...

Страница 8: ...charge as they may cause ignition of these in flammable fluids 6 Do not use plastic vessels to do the washing Metal vessels are recommended 6 Protect the printer against dirt heavy dust and excessive...

Страница 9: ...in an explosion hazard area switch your Ink Jet printer off do not replace the batteries or do not remove them from the printer and follow all instructions and precautions Sparking generated by batte...

Страница 10: ...been used for a long time cannot be charged up to its full capacity There fore in order to form the battery follow three charge and then discharge cy cles See figures A and C 1 Pull out plug 15 from s...

Страница 11: ...he ink container is detached Follow the steps below in order to install the container 1 Remove the container from pack ing 10 2 Position the container in relation to the back of the printer so that th...

Страница 12: ...o not leave the printer with the ink container detached for a longer time than that required to replace the container While detaching or install ing the container be careful not to splash anyone or an...

Страница 13: ...rinter on if the printer is on and the radio communica tions link operates properly Connecting the Printer with Computer See figures B D and F The printer communicates with the computer through module...

Страница 14: ...t window cursor position in the text sample position of the cursor total length of text printer font type at the current cursor position paste a text from the clipboard Ctrl V preview a print preview...

Страница 15: ...of the list and marked with the symbol 3 Move the cursor to another posi tion and insert another font change marker If only one font change marker has been inserted all characters from the marker pos...

Страница 16: ...riable fields no Windows fonts can be used Date and Time In order to synchronize the date and time of your printer with those of your computer move to the Date tab and click the and keys successively...

Страница 17: ...rd 1 Sunday 2 Monday 3 Tuesday 7 Saturday The numbering of weekdays can be changed in the following way on checking the time on your computer by clicking the key or on your printer by clicking the key...

Страница 18: ...on the text edit line press the right mouse button or the MENU but ton and select the command Define variable field in the menu displayed Then select Up counter Down counter in the list displayed The...

Страница 19: ...to the database variable field The database handling option is available for the EBS250C printers after an enable code has been typed in Contact your printer distributor to obtain the code After the c...

Страница 20: ...In order to choose other parameters column headings double click on the database variable field in the list dis played in the Variable Field window In order to establish connection be tween the printe...

Страница 21: ...ument entitled HANDJET EBS 250 Printer Database Operating Manual Print Preview On creating a text to be printed with the use of the variable fields you can check for proper operation of the counters u...

Страница 22: ...ings of the parameter can vary between 5 and 4000 with the increment of 1 The settings of the Text width print parameter are restricted not only by the above mentioned range limits The current setting...

Страница 23: ...direction parameter is set to Disabled this parameter is available in the Advance tab sheet after the Adv options box has been ticked the printer travels from left to right or from right to left The...

Страница 24: ...in relation to a reference point for example the edge of an object The settings of the Print delay pa rameter range from 0 to 9999 with the increment of 1 Distance between Texts The Rep distance param...

Страница 25: ...om the Printer control menu Wait until an O K message is displayed in the transmission status window If you use the extended parameter panel which is available after the Adv options box has been ticke...

Страница 26: ...INT ON OFF Lamp 17 goes out If the Stop printing method parame ter is set to Complete stop and you press button 18 lamp 17 will flash This means that you have pressed release button 5 but not finished...

Страница 27: ...hange marker 4 Transfer the text to the printer and you can start printing Each text is selected and printed with release button 5 The number of texts to be printed in separate lines is not limited In...

Страница 28: ...for a while until bussing is heard from buzzer 32 Such a switching operation can be performed regardless whether the printer is in the print state lamp 17 lights or not The buzzing from buzzer 32 is d...

Страница 29: ...in to the printer s movable bearing based parts or inner electronic subassemblies unintentionally In effect the roll guides may seize or ever lockup permanently and the shaft encoder position sensor a...

Страница 30: ...of ink have been con sumed however not less frequently than every four years the built in ink filter should be checked and replaced if need be It is recommended that the replacement operation be perfo...

Страница 31: ...sive lines Maximum number of characters per text 1300 including control characters for the printer s built in fonts Number of texts and accompa nying print parameter stored in the printer s memory at...

Страница 32: ...Class 1 2 400 2 485 GHz up to 100 m according to land surface configuration Power supply Battery powered with a pack of 3 Li Ion cells Approximate operating time with the battery fully charged 50 hou...

Страница 33: ...C if acetone or etha nol based ink is used for printing Humidity Up to 95 without steam condensa tion at temperatures higher than the dew point the printer can be operated when it rains provided that...

Страница 34: ...g instructions and user support files instructions advice help in electronic form 1 disc Other elements to be delivered with the order as part of the system or separately Double guide rolls to support...

Страница 35: ...25 D 51588 N mbrecht Germany 49 0 2293 939 0 49 0 2293 939 3 http www ebs inkjet de EBS Ink Jet Systems Poland Sp z o o ul Tarnogajska 13 50 512 Wroclaw Poland 48 71 367 04 11 48 71 373 32 69 http ww...

Отзывы: