CPX200NWB ALARM CONTROL UNIT – INSTALLER MANUAL
34 / 118
o
0 – no fuction
o
1 – arm
o
2 – disarm
o
3 – alarm
o
4 – silent alarm
o
5 – enable output 1
o
6 – enable output 2
o
7 – enable output 3
o
8 – disable output 1
o
9 – disable output 2
o
10 – disable output 3
Note:
„Alarm” function is triggering an alarm with audible signal.
„Silent alarm” function is triggering an alarm without audible signal.
Alarms from remote control can be generated regardless of whether or not the partition is
armed. For normal and silent alarm can be sent a message to the monitoring station,
depending on the configuration of the control panel.
Example:
a)
delete a remote control no. 1:
b)
add a remote control no. 1:
4.3.10.2.
Delete all remote controllers
To remove all remote controllers from the system, enter the following function:
After entering the function PROG LED is blinking, the other LEDs are off. Pressing
key
deletes all remote controllers, generating 3 beeps and exit the function. If you press
key will exit the function and remote controllers will not be erased.
4.3.11.
Emergency buttons
To configure emergency buttons, use the following pattern:
<XX> <Y>
where:
XX
– emergency button: