CPX200NW ALARM CONTROL UNIT – USER MANUAL
14 / 28
EN
7.
PARTITION HANDLING
7.1.
ARMING / DISARMING WITH SELECTING PARTITIONS
1.
Enter the number of the function
and confirm using
. Then enter
the user code and press
. 3-tone beep will confirm the correct code
input.
Note: If incorrect code is entered the keypad will emit long
constant sound. Enter the correct code once again.
2.
LEDs 1 and 2 will display the current partition state. LED on – partition armed,
LED off - partition disarmed. Only LEDs indicating the partitions the user has
access to will be on.
3.
To change the partition state press buttons with partition numbers (LEDs with
relevant partition number will go on/off). Confirm the change of partition state
using
button. 3 beeps will confirm the change. To cancel the entered
changes, press
.
4.
If partition arming was selected, the keypad will indicate counting the time for
leaving the facility. Leave the facility before the time for leaving expires.
After it is armed the ARMED LED will be constantly on.
5.
If partition disarming is selected, the relevant partition will be immediately
disarmed.
7.2.
QUICK ARMING / DISARMING PARTITIONS
1.
Enter the number of the function (
for partition one or
for partition two) and confirm using
. Then enter the user code and press
. 3-tone beep will confirm the correct code input.
Note: If incorrect code is entered the keypad will emit long
constant sound. Enter the correct code once again.
2.
If partition arming was selected, the keypad will indicate counting the time for
leaving the facility. Leave the facility before the time for leaving expires.
After it is armed the ARMED LED will be constantly on.
3.
If partition disarming is selected, the relevant partition will be immediately
disarmed.