AVA PRO - Assembly instructions for the CPX300W alarm control panel
7
/
23
SMS alerts for 10 different users,
Battery connection reverse polarity protection,
5 operating switches on the motherboard,
A history of events that allows you to view a minimum of 5000 recent events.
2.2.
Technical parameters
Table 1. Technical parameters related to the control panel.
Available transmission channels
1) GPRS, SMS
2) ETHERNET or WiFi
Frequency bands
*
868 MHz (ITU Region 1)
915 / 921 MHz (ITU Regions 2 and 3)
(optional 433 MHz with MOD-RF344
Number of supported keypads KP3W
max. 8
Number of supported sirens
BM8000PLx-C3W
max. 8
Number of supported PIR-CAM-30 devices
max. 8
Power supply voltage:
18 V AC (16-20 V AC)
Transformer power required:
min. 20 VA
Current consumption @18VAC
(average / max)
**
85 mA / 130 mA @18VAC / in 2G mode
~ with MOD-GSM-2G (modem uBlox Sara-G350)
78 mA / 130 mA @18VAC / in 3G mode
~ with MOD-GSM-3G (modem uBlox Sara-U201)
Current consumption with battery supply @13VDC
(average / max)
**
60 mA / 120 mA @13VDC / in 2G mode
~ with MOD-GSM-2G (modem uBlox Sara-G350)
55 mA / 112,5 mA @13VDC / in 3G mode
~ with MOD-GSM-3G (modem uBlox Sara-U201)
Supply voltage:
230 V AC (acceptable: 190-250 V AC)
Power consumption (medium / maximum):
3 W / 20 W@230 V AC
Battery charging current:
max. 350 mA
Charging voltage:
13.8 V
Supported batteries:
lead-acid 12 V
Low battery signalling voltage:
11 V
Battery disconnection voltage at too low capacity:
below 9 V
Working temperature:
from -10°C to +55°C
Operating humidity range:
93±3%
Dimensions of the board:
151 x 77 x 30 mm
*
National regulations may apply.
**
Average for conditions: charged battery, server connection set up, keyboard, no sensors.