3.2 Nominal data
Motor
M6E110-EF
Phase
1~
1~
Nominal voltage / VAC
230
230
Frequency / Hz
50
60
Method of obtaining
data
fa
fa
Valid for approval/
standard
-
-
Speed (rpm) / min
-1
935
1075
Power consumption / W
225
360
Current draw / A
1.0
1.6
Capacitor / µF
8
8
Capacitor voltage / VDB
400
400
Capacitor standard
S0 (CE)
S0 (CE)
Max. back pressure / Pa
70
90
Min. ambient
temperature / °C
-40
-40
Max. ambient
temperature / °C
65
65
Starting current / A
2.3
2.2
ml = Max. load · me = Max. efficiency · fa = Free air
cs = Customer specification · ce = Customer equipment
Subject to change
3.3 Technical description
Weight
17.66 kg
Size
500 mm
Motor size
110
Rotor surface
Painted black
Terminal box material
PC/ABS plastic
Blade material
Press-fitted sheet steel blank, sprayed
with PP plastic
Fan housing material
Sheet steel, galvanized and coated with
cement-gray plastic (RAL 7033)
Guard grille material
Steel, coated with cement-gray plastic
(RAL 7033)
Number of blades
5
Airflow direction
A
Direction of rotation
Clockwise, viewed toward rotor
Degree of protection
IP54
Insulation class
"F"
Moisture (F) /
Environmental (H)
protection class
H2+T
Ambient temperature
note
Occasional start-up at temperatures
between -40°C and -25°C is permitted.
For continuous operation at ambient
temperatures below -25°C (such as
refrigeration applications), use must be
made of a fan design with special low-
temperature bearings.
Installation position
Shaft horizontal or rotor on top; rotor on
bottom on request
Condensation
drainage holes
On stator side
Mode
S1
Motor bearing
Ball bearing
Touch current
according to IEC
60990 (measuring
circuit Fig. 4, TN
system)
<= 3.5 mA
Electrical hookup
Terminal box
Motor protection
Thermal overload protector (TOP) with
basic insulation
with cable
Axial
Protection class
assignment
I; If a protective earth is connected by
the customer
This component for installation may
have several local protection classes.
This information relates to this
component’s basic design.
The final protection class is based on
the component’s intended installation and
connection.
Motor capacitor
according to EN 60252-
1 in safety protection
class
S0
Conformity with
standards
EN 60034-1 (2010)
Comment on CE
Operation only permitted outside the
European Economic Area
Approval
CSA C22.2 No. 100; EAC; VDE; UL
1004-1
;
Use the device in accordance with its degree of protection.
Information on surface quality
The surfaces of the products conform to the generally applicable industrial
standard. The surface quality may change during the production period.
This has no effect on strength, dimensional stability and dimensional
accuracy.
The color pigments in the paints used perceptibly react to UV light over
the course of time. The product is to be protected against UV radiation to
prevent the formation of patches and fading. Changes in color are not a
reason for complaint and are not covered by the warranty. UV radiation
in the frequency range and the intensity of natural solar radiation has no
effect on the technical properties of the products.
3.4 Mounting data
Further mounting data can be taken from the product drawing or Chapter
4.1 Mechanical connection as required.
Strength class of
screws
8.8
;
Secure the screws against unintentional loosening (e.g. use self-
locking screws).
3.5 Transport and storage conditions
Max. permitted
ambient temp. for
motor (transport/
storage)
+80 °C
Min. permitted
ambient temp. for
motor (transport/
storage)
-40 °C
Item no. 13600-5-9970 · ENU · Change 265731 · Approved 2022-09-30 · Page 5 / 12
ebm-papst Mulfingen GmbH & Co. KG · Bachmühle 2 · D-74673 Mulfingen · Phone +49 (0) 7938 81-0 · Fax +49 (0) 7938 81-110 · [email protected] · www.ebmpapst.com