ebm-papst W4S250-DI02-01 Скачать руководство пользователя страница 5

Part Number

  

Operating Instructions 

Item no. LS-119.

 

Revision 003

 

Release 24/05/2016

 

Page 5 of 8

 

ebm-papst A&NZ Pty Ltd

 

10 Oxford Road · Laverton North VIC 3026 · Phone +61 (03) 9360 6400 · Fax +61 (03) 9360 6464 

ABN 33 115 927 556 

NSW Phone +61 (02) 9827 6400 · NSW Fax +61 (02) 9827 6464 · NZ Phone +64 (09) 525 0245 · NZ Fax +64 (09) 525 0246 
[email protected] · www.ebmpapst.com.au 

W4S250-DI02-01 

3.2

 

Nominal data

 

Motor 

M4S068-CF 

Phase 

1~ 

1~ 

Nominal Voltage / VAC 

230 

230 

Frequency / Hz 

50 

60 

Type of data definition 

Running at free air 

Valid for approval / 
standard  

CE 

CE 

Speed / rpm 

1390 

1600 

Power input / W 

69 

63 

Current draw / A 

0.53 

0.45 

Max. Back pressure / Pa 

80 

80 

Min. ambient temperature / 
°C  

-25

-25

Max. ambient temperature / 
°C  

50 

65 

Starting current / A 

0.85 

0.7 

Max. safe operating speed / 
rpm 

2950 
@ 85 ºC 

2950 
@ 85 ºC 

Subject to alterations 

3.3

 

Technical features

 

Mass 

3.64 kg 

Size 

250 mm 

Surface of rotor 

Coated in black 

Material of blades 

Sheet steel, coated in black 

Number of blades 

Material of guard grille 

Steel phosphate and coated in 
black 

Material of wall ring 

Sheet steel, pre-galvanised 
and coated in black plastic 

Direction of airflow 

“A” 

Direction of rotation 

Counter clockwise, seen on 
rotor 

Type of protection 

IP 44 

Moisture (F) / 
Environmental (H) 
protection class 

H0+ 

Humidity class 

F1-2 

Mounting position 

Shaft horizontal or rotor on 
bottom; rotor on top on request 

Condensate discharge 
holes 

Rotor-side 

Operation mode 

S1 

Motor bearing 

Ball bearing 

Touch current acc. IEC 
60990 (measuring 
network Fig. 4, TN 
system)  

< 0.75 mA 

Motor protection 

Thermal overload protector 
(TOP) wired internally 

Cable exit 

Lateral 

Protection class 

I (if protective earth is 
connected by customer) 

Product conforming to 
standard 

CE 

Approval 

EAC 

For cyclic speed loads, note that the rotating parts of 
the device are designed for maximum one million 

load cycles. If you have specific questions, contact 
ebm-papst A&NZ for support. 

3.4

 

Mounting data

 

 

Secure the mounting screws against accidentally coming 
loose (e.g. by using self-locking screws).  

You can obtain additional mounting data from the product 
drawing if necessary. 

3.5

 

 Transport and storage conditions 

 

Use the device in accordance with its protection type. 

Max. permissible ambient motor 
temp. (transp./storage) 

+ 80 °C

Min. permissible ambient motor 
temp. (transp./storage) 

- 40 °C

Содержание W4S250-DI02-01

Страница 1: ...nd people These operating instructions are to be regarded as part of this device If the device is sold or transferred the operating instructions must accompany it These operating instructions may be duplicated and forwarded for information about potential dangers and their prevention 1 1 Levels of hazard warnings These operating instructions use the following hazard levels to indicate potentially ...

Страница 2: ... adequate protection for the device Shut down the device immediately if you detect a missing or ineffective protective feature 1 6 Mechanical movement DANGER Rotating device Body parts that come into contact with the rotor and impeller can be injured Secure the device against accidental contact Before working on the system machine wait until all parts have come to a standstill WARNING Rotating dev...

Страница 3: ... with the permitted ambient temperature see chapter 3 5 Transport and storage conditions and chapter 3 2 Nominal data Operating the device with all protective features in place Minding the operating instructions Improper use Using the device in the following ways is particularly prohibited and may cause hazards Operating the device with an imbalance e g caused by dirt deposits or icing Moving air ...

Страница 4: ...1 03 9360 6464 ABN 33 115 927 556 NSW Phone 61 02 9827 6400 NSW Fax 61 02 9827 6464 NZ Phone 64 09 525 0245 NZ Fax 64 09 525 0246 sales ebmpapst com au www ebmpapst com au W4S250 DI02 01 3 TECHNICAL DATA 3 1 Product drawing AIRFLOW DIRECTION All dimensions are in mm Direction of air flow V Depth of screw max 5 mm Cable requirements Connection line PVC 3G 0 5mm2 3x lead tips crimped ...

Страница 5: ...ng Sheet steel pre galvanised and coated in black plastic Direction of airflow A Direction of rotation Counter clockwise seen on rotor Type of protection IP 44 Moisture F Environmental H protection class H0 Humidity class F1 2 Mounting position Shaft horizontal or rotor on bottom rotor on top on request Condensate discharge holes Rotor side Operation mode S1 Motor bearing Ball bearing Touch curren...

Страница 6: ...end is connected in a dry environment Connect the device only to circuits that can be switched off using an all pole disconnecting switch 4 2 1 Prerequisites Check whether the data on the type plate agree with the connection data Before connecting the device ensure that the supply voltage matches the operating voltage of the device Only use cables designed for current according to the type plate F...

Страница 7: ...t A NZ for repair or replacement WARNING Terminals and connections have voltage even with a unit that is shut off Electric shock Wait five minutes after disconnecting the voltage at all poles before opening the device CAUTION The motor restarts automatically when operating voltage is applied e g after a power failure Danger of injury Keep out of the danger zone of the device When working on the de...

Страница 8: ...ealth protection are fixed criteria The following section contains recommendations for ecological disposal of the product and its components 5 3 1 Country specific legal requirements NOTE Country specific legal requirements Always observe the applicable country specific legal regulations with regard to the disposal of products or waste occurring in the various phases of the life cycle The correspo...

Отзывы: