ebm-papst W4D400-CP12-31 Скачать руководство пользователя страница 5

Operating instructions

W4D400-CP12-31

Translation of the original operating instructions

3.2 Nominal data

Motor

M4D074-EI

Phase

3~

3~

3~

3~

Nominal voltage / VAC

230

230

400

400

Wiring

Δ

Δ

Y

Y

Frequency / Hz

50

60

50

60

Method of obtaining
data

fa

fa

fa

fa

Valid for approval/
standard

CE

CE

CE

CE

Speed (rpm) / min

-1

1450

1690

1450

1690

Power consumption / W

135

185

135

185

Current draw / A

0.76

0.68

0.44

0.39

Max. back pressure / Pa

105

120

105

120

Min. ambient
temperature / °C

-25

-25

-25

-25

Max. ambient
temperature / °C

40

40

40

40

Starting current / A

3.0

3.0

1.7

1.7

ml = Max. load · me = Max. efficiency · fa = Free air

cs = Customer specification · ce = Customer equipment

Subject to change

3.3 Data according to Commission Regulation (EU) 327/
2011

Actual

Req. 2015

01 Overall efficiency η

es

/ %

33

29.3

02 Measurement category

A

03 Efficiency category

Static

04 Efficiency grade N

43.7

40

05 Variable speed drive

No

06 Year of manufacture

The year of manufacture is specified on the
product's rating label.

07 Manufacturer

ebm-papst Mulfingen GmbH & Co. KG
Amtsgericht (court of registration) Stuttgart ·
HRA 590344
D-74673 Mulfingen

08 Type

W4D400-CP12-31

09 Power consumption P

e

/ kW

0.2

09 Air flow q

v

/ m³/h

2805

09 Pressure increase total p

sf

/

Pa

92

10 Speed (rpm) n / min

-1

1390

11 Specific ratio

*

1.00

12 Recycling/disposal

Information on recycling and disposal is
provided in the operating instructions.

13 Maintenance

Information on installation, operation and
maintenance is provided in the operating
instructions.

14 Additional components

Components used to calculate the energy
efficiency that are not apparent from the
measurement category are detailed in the
CE declaration.

*

Specific ratio = 1 + p

fs

/ 100 000 Pa

Data obtained at optimum efficiency level. The ErP data is determined using a motor-impeller

combination in a standardized measurement setup.

3.4 Technical description

Weight

7.98 kg

Size

400 mm

Motor size

74

Rotor surface

Painted black

Blade material

Sheet steel, painted black

Fan housing material

Sheet steel, pre-galvanized and coated
with black plastic (RAL 9005)

Guard grille material

Steel, coated with black plastic (RAL
9005)

Number of blades

5

Airflow direction

A

Direction of rotation

Clockwise, viewed toward rotor

Degree of protection

IP44; installation- and position-dependent
as per EN 60034-5

Insulation class

"B"

Moisture (F) /
Environmental (H)
protection class

H1

Installation position

Shaft horizontal or rotor on bottom; rotor
on top on request

Condensation
drainage holes

On rotor side

Mode

S1

Motor bearing

Ball bearing

Touch current
according to IEC
60990 (measuring
circuit Fig. 4, TN
system)

< 0.75 mA

with cable

Variable

Protection class

I (with customer connection of protective
earth)

Conformity with
standards

EN 60335-1, motor does not have
factory-installed overheating protection; CE

Approval

EAC; CCC

With regard to cyclic speed loads, note that the rotating parts of
the device are designed for a maximum of one million load
cycles. If you have special questions, consult ebm-papst for
support.

;

Use the device in accordance with its degree of protection.

Information on surface quality

The surfaces of the products conform to the generally applicable industrial
standard. The surface quality may change during the production period.
This has no effect on strength, dimensional stability and dimensional
accuracy.
The color pigments in the paints used perceptibly react to UV light over
the course of time. This does not however in any way affect the
technical properties of the products. The product is to be protected against
UV radiation to prevent the formation of patches and fading. Changes in
color are not a reason for complaint and are not covered by the warranty.

Item no. 13518-5-9970 · ENU · Change 205353 · Approved 2021-02-09 · Page 5 / 11

ebm-papst Mulfingen GmbH & Co. KG · Bachmühle 2 · D-74673 Mulfingen · Phone +49 (0) 7938 81-0 · Fax +49 (0) 7938 81-110 · [email protected] · www.ebmpapst.com

Содержание W4D400-CP12-31

Страница 1: ...ned and authorized technical staff Only authorized specialists are permitted to install the device to carry out a test run and to perform work on the electrical installation 1 3 Basic safety rules 1 1...

Страница 2: ...vice Risk of injury to body parts coming into contact with the rotor or the impeller Secure the device against accidental contact Before working on the system machine wait until all parts have come to...

Страница 3: ...prohibited and could be hazardous Operating the device in an unbalanced state e g due to dirt deposits or ice formation Resonant operation operation with severe vibration This also includes vibration...

Страница 4: ...oduct drawing All dimensions in mm 1 Direction of air flow A 2 Cable PVC 7G 0 5 mm 7x crimped splices Item no 13518 5 9970 ENU Change 205353 Approved 2021 02 09 Page 4 11 ebm papst Mulfingen GmbH Co K...

Страница 5: ...on Weight 7 98 kg Size 400 mm Motor size 74 Rotor surface Painted black Blade material Sheet steel painted black Fan housing material Sheet steel pre galvanized and coated with black plastic RAL 9005...

Страница 6: ...tective earth DANGER Faulty insulation Risk of fatal injury from electric shock Use only cables that meet the specified installation regulations for voltage current insulation material capacity etc Ro...

Страница 7: ...after consultation with ebm papst For operation with variable frequency drives install sinusoidal filters that work on all poles phase phase and phase ground between the drive and the motor During op...

Страница 8: ...two phases Three phase motor Delta connection Y Star connection L1 U1 black L2 V1 blue L3 W1 brown U2 green V2 white W2 yellow PE green yellow Item no 13518 5 9970 ENU Change 205353 Approved 2021 02 0...

Страница 9: ...connection last 5 MAINTENANCE MALFUNCTIONS POSSIBLE CAUSES AND REMEDIES Do not perform any repairs on your device Send the device to ebm papst for repair or replacement WARNING Live terminals and conn...

Страница 10: ...ck formation Visual inspection At least every 6 months Replace device Abnormal bearing noise acoustic At least every 6 months Replace device 5 3 Disposal For ebm papst environmental protection and res...

Страница 11: ...r internal wiring Electrolytic capacitors Dispose of electronic components employing the proper procedures for electronic scrap Please contact ebm papst for any other questions on disposal Item no 135...

Отзывы: