ebm-papst W4D300-CP28-30 Скачать руководство пользователя страница 5

Operating instructions

W4D300-CP28-30

Translation of the original operating instructions

3.2 Nominal data

Motor

M4D068-CF

Phase

3~

3~

3~

3~

Nominal voltage in VAC

230

230

400

400

Connection

Δ

Δ

Y

Y

Frequency in Hz

50

60

50

60

Type of data definition

fa

fa

fa

fa

Valid for approval /
standard

CE

CE

CE

CE

Speed in min

-1

1370

1540

1370

1540

Power input in W

60

75

60

75

Current draw in A

0.29

0.26

0.17

0.15

Max. back pressure in Pa

90

60

90

60

Max. ambient
temperature in °C

45

40

45

40

ml = max. load · me = max. efficiency · fa = running at free air

cs = customer specs · cu = customer unit

Subject to alterations

3.3 Technical description

Mass

4 kg

Size

300 mm

Surface of rotor

Coated in black

Material of blades

Sheet steel, coated in black

Material of wall ring

Sheet steel, pre-galvanised and coated in
black plastic

Material of guard grille

Steel, phosphated and coated in black
plastic

Number of blades

5

Direction of air flow

"V"

Direction of rotation

Counter-clockwise, seen on rotor

Type of protection

IP 44

Insulation class

"B"

Humidity class

F1-2

Mounting position

Shaft horizontal or rotor on bottom; rotor
on top on request

Condensate discharge
holes

Rotor-side

Operation mode

S1

Motor bearing

Ball bearing

Leakage current

< 0.75 mA

Cable exit

Axial

Protection class

I (if protective earth is connected by
customer)

Product conforming
to standard

EN 60335-1

For cyclic speed loads, note that the rotating parts of the device
are designed for maximum one million load cycles. If you have
specific questions, contact ebm-papst for support.

3.4 Mounting data

For depth of screw, see chapter 3.1 Graphic rendition of products

;

Secure the mounting screws against accidentally coming loose (e.g.
by using self-locking screws).

Strength class for
mounting screws

8.8

You can obtain additional mounting data from the product drawing if
necessary.

3.5 Transport and storage conditions

;

Use the device in accordance with its protection type.

Max. permissible
ambient motor temp.
(transp./ storage)

+ 80 °C

Min. permissible
ambient motor temp.
(transp./storage)

- 40 °C

Item no.: 10556-5-9970 · Revision: 68158 · Print-out: 2012-02-24 · Y. Uhlmann (VM-TDO) · Page 5 / 9

ebm-papst Mulfingen GmbH & Co. KG · Bachmühle 2 · D-74673 Mulfingen · Phone +49 7938 81-0 · Fax +49 7938 81-110 · [email protected] · www.ebmpapst.com

Содержание W4D300-CP28-30

Страница 1: ...em Only trained and authorised specialist personnel are permitted to transport unpack assemble operate or maintain the device or to use it in any other manner 1 3 Basic safety rules 1 1 3 Basic safety...

Страница 2: ...entangled and pulled into the device You could be injured Do not wear any loose clothing or jewellery while working on rotating parts Protect long hair by wearing a cap 1 7 Emission WARNING Depending...

Страница 3: ...lowing ways is particularly prohibited and may cause hazards Operating the device with an imbalance e g caused by dirt deposits or icing Moving air that contains abrasive particles Moving highly corro...

Страница 4: ...oducts All measures have the unit mm 1 Connection line PVC 7x brass lead tips crimped 2 Direction of air flow V Item no 10556 5 9970 Revision 68158 Print out 2012 02 24 Y Uhlmann VM TDO Page 4 9 ebm p...

Страница 5: ...lass F1 2 Mounting position Shaft horizontal or rotor on bottom rotor on top on request Condensate discharge holes Rotor side Operation mode S1 Motor bearing Ball bearing Leakage current 0 75 mA Cable...

Страница 6: ...switch 4 2 1 Prerequisites Check whether the data on the type plate agree with the connection data Before connecting the device ensure that the supply voltage matches the operating voltage of the dev...

Страница 7: ...phases are reversed Delta connection Y Star connection L1 black L2 blue L3 brown U1 black V1 blue W1 brown U2 green V2 white W2 yellow Item no 10556 5 9970 Revision 68158 Print out 2012 02 24 Y Uhlman...

Страница 8: ...tarts automatically when operating voltage is applied e g after a power failure Danger of injury Keep out of the danger zone of the device When working on the device switch off the mains supply voltag...

Страница 9: ...of the device Mounting the connection lines Visual inspection At least every 6 months Fasten Mounting of protective earth connection Visual inspection At least every 6 months Fasten Check the insulat...

Отзывы: