background image

Operating instructions

W3G500-GF48-51

Translation of the original operating instructions

4.4 Connection diagram

Drawing preliminary!

No.

Conn.

Designation

Color

Function/assignment

1

1,2

PE

green/
yellow

Protective earth

1

3

N

blue

Power supply, neutral conductor, 50/60 Hz

1

4

L

black

Power supply, phase, 50/60 Hz

1

5

COM

white 1

Floating status contact, break for failure (2 A, max. 250 VAC, min. 10 mA, AC1)

1

6

NC

white 2

Floating status contact, break for failure

2

8

0 - 10 V

yellow

Control input, set value 0-10 VDC, impedance 100 kOhm, SELV

2

11

10 VDC

red

Voltage output 10 VDC (±3%), max. 10 mA, power supply for external devices (e.g.
potentiometers), SELV

2

12

GND

blue

Reference ground for control interface, SELV

Item no. 50319-5-9970 · ENU · Change 89187 · Approved 2016-04-15 · Page 8 / 11

ebm-papst Mulfingen GmbH & Co. KG · Bachmühle 2 · D-74673 Mulfingen · Phone +49 (0) 7938 81-0 · Fax +49 (0) 7938 81-110 · [email protected] · www.ebmpapst.com

Содержание W3G500-GF48-51

Страница 1: ...used by suitably qualified trained and authorized technical staff Only authorized specialists are permitted to install the device to carry out a test run and to perform work on the electrical install...

Страница 2: ...ice in customer equipment Verify that the entire setup is EMC compliant 1 7 Mechanical movement DANGER Rotating device Risk of injury to body parts coming into contact with the rotor or the impeller S...

Страница 3: ...ve devices Following the operating instructions Improper use In particular operating the device in the following ways is prohibited and could be hazardous Operating the device in an unbalanced state e...

Страница 4: ...dimensions in mm 1 Direction of air flow V 2 Cable PVC AWG18 5x crimped ferrules 3 Cable PVC AWG22 3x crimped ferrules Item no 50319 5 9970 ENU Change 89187 Approved 2016 04 15 Page 4 11 ebm papst Mu...

Страница 5: ...is determined using a motor impeller combination in a standardized measurement setup 3 4 Technical description Weight 10 5 kg Fan size 500 mm Rotor surface Painted black Electronics housing material D...

Страница 6: ...tall the undamaged device in accordance with your application CAUTION Possible damage to the device If the device slips during installation serious damage can result Ensure that the device is securely...

Страница 7: ...ty to interference reactive currents can be measured in the supply line even when the motor is at a standstill and the line voltage is switched on The values are typically less than 50 mA At the same...

Страница 8: ...k for failure 2 A max 250 VAC min 10 mA AC1 1 6 NC white 2 Floating status contact break for failure 2 8 0 10 V yellow Control input set value 0 10 VDC impedance 100 kOhm SELV 2 11 10 VDC red Voltage...

Страница 9: ...ion detection error An automatic restart follows Blocked rotor After the blockage is removed the motor restarts automatically Line undervoltage line voltage outside of permitted nominal voltage range...

Страница 10: ...t operates an environmental management system which is certified in accordance with ISO 14001 and rigorously implemented around the world on the basis of German standards Right from the development st...

Страница 11: ...spose of electronic components employing the proper procedures for electronic scrap Please contact ebm papst for any other questions on disposal Item no 50319 5 9970 ENU Change 89187 Approved 2016 04...