background image

Operating instructions

W3G400-IC22-53

Translation of the original operating instructions

Fans installed upright

Fig. 2: Cable routing for fans installed upright.
The cables must always be routed downward.

Item no. 51883-5-9970 · ENU · Change 93960 · Approved 2017-06-23 · Page 8 / 12

ebm-papst Mulfingen GmbH & Co. KG · Bachmühle 2 · D-74673 Mulfingen · Phone +49 (0) 7938 81-0 · Fax +49 (0) 7938 81-110 · [email protected] · www.ebmpapst.com

Содержание W3G400-IC22-53

Страница 1: ...erwise used by suitably qualified trained and authorized technical staff Only authorized specialists are permitted to install the device to carry out a test run and to perform work on the electrical i...

Страница 2: ...after installing the device in customer equipment Verify that the entire setup is EMC compliant 1 7 Mechanical movement DANGER Rotating device Risk of injury to body parts coming into contact with th...

Страница 3: ...ons Improper use In particular operating the device in the following ways is prohibited and could be hazardous Operating the device in an unbalanced state e g due to dirt deposits or ice formation Res...

Страница 4: ...ensions in mm 1 Direction of air flow V 2 Cable PVC AWG18 5x tin plated wire ends 3 Cable PVC AWG22 3x tin plated wire ends Item no 51883 5 9970 ENU Change 93960 Approved 2017 06 23 Page 4 12 ebm paps...

Страница 5: ...in a standardized measurement setup 3 4 Technical description Weight 8 52 kg Fan size 400 mm Rotor surface Painted black Electronics housing material Die cast aluminum Blade material Press fitted she...

Страница 6: ...of the impeller could be damaged Carefully set down the fan on a soft surface Make sure the blades are not subjected to load Following installation make sure the impeller moves easily and that the bl...

Страница 7: ...symbol and a hole 4 2 2 Reactive currents Because of the EMC filter integrated for compliance with EMC limits interference emission and immunity to interference reactive currents can be measured in th...

Страница 8: ...pright Fig 2 Cable routing for fans installed upright The cables must always be routed downward Item no 51883 5 9970 ENU Change 93960 Approved 2017 06 23 Page 8 12 ebm papst Mulfingen GmbH Co KG Bachm...

Страница 9: ...ting instructions 4 4 Connection diagram Drawing preliminary Item no 51883 5 9970 ENU Change 93960 Approved 2017 06 23 Page 9 12 ebm papst Mulfingen GmbH Co KG Bachm hle 2 D 74673 Mulfingen Phone 49 0...

Страница 10: ...power supply Disconnect the device from the power supply When disconnecting be sure to disconnect the ground connection last 5 INTEGRATED PROTECTIVE FEATURES The integrated protective functions cause...

Страница 11: ...months Open holes Welds for crack formation Visual inspection At least every 6 months Replace device Abnormal bearing noise acoustic At least every 6 months Replace device 6 3 Disposal For ebm papst e...

Страница 12: ...aterials and are therefore to be treated in the same manner The materials concerned are as follows Miscellaneous insulators used in the terminal box Power cables Cables for internal wiring Electrolyti...

Отзывы: