ebm-papst W3G400-CC22-51 Скачать руководство пользователя страница 9

Operating instructions

W3G400-CC22-51

Translation of the original operating instructions

4.4 Connection diagram

Drawing preliminary!

Item no. 51110-5-9970 · ENU · Change 211129 · Approved 2020-07-16 · Page 9 / 12

ebm-papst Mulfingen GmbH & Co. KG · Bachmühle 2 · D-74673 Mulfingen · Phone +49 (0) 7938 81-0 · Fax +49 (0) 7938 81-110 · [email protected] · www.ebmpapst.com

Содержание W3G400-CC22-51

Страница 1: ...authorized specialists are permitted to install the device to carry out a test run and to perform work on the electrical installation 1 3 Basic safety rules 1 1 3 Basic safety rules The safety hazard...

Страница 2: ...vels occur following installation appropriate shielding measures have to be taken by the user NOTE Electrical or electromagnetic interference after installing the device in customer equipment Verify t...

Страница 3: ...prohibited and could be hazardous Operating the device in an unbalanced state e g due to dirt deposits or ice formation Resonant operation operation with severe vibration This also includes vibration...

Страница 4: ...dimensions in mm 1 Direction of air flow V 2 Cable PVC AWG18 5x crimped ferrules 3 Cable PVC AWG22 3x crimped ferrules Item no 51110 5 9970 ENU Change 211129 Approved 2020 07 16 Page 4 12 ebm papst Mu...

Страница 5: ...andardized measurement setup 3 4 Technical description Weight 8 5 kg Size 400 mm Motor size 84 Rotor surface Painted black Electronics housing material Die cast aluminum Blade material Press fitted sh...

Страница 6: ...ckaging by the fan housing Strictly avoid shocks Wear safety shoes and cut resistant safety gloves CAUTION The blades of the impeller could be damaged Carefully set down the fan on a soft surface Make...

Страница 7: ...he motor is at a standstill and the line voltage is switched on The values are typically in the range 250 mA At the same time the effective power in this operating state operational readiness is typic...

Страница 8: ...U shaped loop Fans installed upright Fig 2 Cable routing for fans installed upright The cables must always be routed downward Item no 51110 5 9970 ENU Change 211129 Approved 2020 07 16 Page 8 12 ebm...

Страница 9: ...ting instructions 4 4 Connection diagram Drawing preliminary Item no 51110 5 9970 ENU Change 211129 Approved 2020 07 16 Page 9 12 ebm papst Mulfingen GmbH Co KG Bachm hle 2 D 74673 Mulfingen Phone 49...

Страница 10: ...ound connection last 5 INTEGRATED PROTECTIVE FEATURES The integrated protective functions cause the motor to switch off automatically in the event of the faults described in the table Fault Safety fea...

Страница 11: ...y cleaning agents used If severe corrosion is visible on load bearing or rotating parts switch off the device immediately and replace it Repair of load bearing or rotating parts is not permitted Opera...

Страница 12: ...nts could drop off during disassembly This can result in fatal or serious injury and material damage Secure components before unfastening to stop them falling 6 3 3 Component disposal The products are...

Отзывы: