background image

Operating instructions

W2G115-AD17-01

Translation of the original operating instructions

4.4 Connection diagram

Line

No.

Signal

Colour

Function / assignment

1

1

UN +24V

red

Power 24 V/voltage range refer to rating plate,
residual ripple ± 3.5%

1

2

GND

blue

Reference mass

Item no.: 51600-5-9970 · Revision: 75470 · Print-out: 2012-02-24 · Y. Uhlmann (VM-TDO) · Page 7 / 9

ebm-papst Mulfingen GmbH & Co. KG · Bachmühle 2 · D-74673 Mulfingen · Phone +49 7938 81-0 · Fax +49 7938 81-110 · [email protected] · www.ebmpapst.com

Содержание W2G115-AD17-01

Страница 1: ...ist personnel are permitted to transport unpack assemble operate or maintain the device or to use it in any other manner 1 3 Basic safety rules 1 1 3 Basic safety rules Any safety hazards stemming from the device must be re evaluated once it is installed in the end device Observe the following when working on the unit Do not make any modifications additions or conversions to the device without the...

Страница 2: ... come to a standstill WARNING Rotating device Long hair loose items of clothing and jewellery could become entangled and pulled into the device You could be injured Do not wear any loose clothing or jewellery while working on rotating parts Protect long hair by wearing a cap 1 8 Emission WARNING Depending on the installation and operating conditions a sound pressure level greater than 70 dB A may ...

Страница 3: ...llowing ways is particularly prohibited and may cause hazards Operating the device with an imbalance e g caused by dirt deposits or icing Moving air that contains abrasive particles Moving highly corrosive air e g salt spray mist Exceptions are devices that are intended for salt spray mist and protected accordingly Moving air that contains dust pollution e g suctioning off saw dust Operating the d...

Страница 4: ...products All measures have the unit mm 1 Direction of air flow V 2 Connection line AWG22 2X tin plated lead tips Item no 51600 5 9970 Revision 75470 Print out 2012 02 24 Y Uhlmann VM TDO Page 4 9 ebm papst Mulfingen GmbH Co KG Bachmühle 2 D 74673 Mulfingen Phone 49 7938 81 0 Fax 49 7938 81 110 info1 de ebmpapst com www ebmpapst com ...

Страница 5: ... protective earth is connected by customer Product conforming to standard EN 60335 1 Approval UL 507 CSA C22 2 Nr 113 For cyclic speed loads note that the rotating parts of the device are designed for maximum one million load cycles If you have specific questions contact ebm papst for support 3 4 Mounting data For depth of screw see chapter 3 1 Graphic rendition of products Secure the mounting scr...

Страница 6: ...a dry environment Operate the device with a safely isolated power pack 4 2 1 Prerequisites Check whether the data on the type plate agree with the connection data Before connecting the device ensure that the supply voltage matches the operating voltage of the device Only use cables designed for current according to the type plate For determining the cross section follow the basic principles in acc...

Страница 7: ...signment 1 1 UN 24V red Power supply 24 V voltage range refer to rating plate residual ripple 3 5 1 2 GND blue Reference mass Item no 51600 5 9970 Revision 75470 Print out 2012 02 24 Y Uhlmann VM TDO Page 7 9 ebm papst Mulfingen GmbH Co KG Bachmühle 2 D 74673 Mulfingen Phone 49 7938 81 0 Fax 49 7938 81 110 info1 de ebmpapst com www ebmpapst com ...

Страница 8: ...If control voltage is applied or a speed setpoint is stored the motor automatically restarts e g after a power failure Danger of injury Keep out of the danger zone of the device When working on the device switch off the mains supply voltage and secure the latter from being switched on again Wait until the device stops After working on the device remove any used tools or other objects from the devi...

Страница 9: ...easure Check the protective casing against accidental contact for damage and to ensure that it is intact Visual inspection At least every 6 months Repair or replacement of the device Check the device for damage to blades and housing Visual inspection At least every 6 months Replacement of the device Mounting the connection lines Visual inspection At least every 6 months Fasten Check the insulation...