Operating instructions
W2G115-AD15-13
Translation of the original operating instructions
3.2 Nominal data
Motor
M2G045-BA
Nominal voltage in VDC
12
Nominal voltage
range in VDC
8 .. 16
Type of data definition
fa
Speed in min
-1
2800
Power input in W
4.5
Min. ambient
temperature in °C
- 25
Max. ambient
temperature in °C
+ 72
ml = max. load · me = max. efficiency · fa = running at free air
cs = customer specs · cu = customer unit
Subject to alterations
3.3 Technical description
Mass
0.55 kg
Size
115 mm
Surface of rotor
Coated in black
Material of blades
Sheet steel, coated in black
Material of wall ring
Die-cast aluminium, coated in black
Number of blades
7
Direction of air flow
"V"
Direction of rotation
Counter-clockwise, seen on rotor
Type of protection
IP 22
Insulation class
"B"
Mounting position
Any
Condensate discharge
holes
None
Operation mode
S1
Motor bearing
Ball bearing
Electrical leads
With plug
Motor protection
Reverse polarity and locked-rotor
protection
Product conforming
to standard
EN 60950-1
Approval
UL 507; CSA C22.2 Nr.113
For cyclic speed loads, note that the rotating parts of the device
are designed for maximum one million load cycles. If you have
specific questions, contact ebm-papst for support.
3.4 Mounting data
For depth of screw, see chapter 3.1 Graphic rendition of products
;
Secure the mounting screws against accidentally coming loose (e.g.
by using self-locking screws).
Strength class for
mounting screws
8.8
You can obtain additional mounting data from the product drawing if
necessary.
3.5 Transport and storage conditions
;
Use the device in accordance with its protection type.
Max. permissible
ambient motor temp.
(transp./ storage)
+ 80 °C
Min. permissible
ambient motor temp.
(transp./storage)
-25 °C
Item no.: 50788-5-9970 · Revision: 71812 · Print-out: 2012-02-24 · Y. Uhlmann (VM-TDO) · Page 5 / 9
ebm-papst Mulfingen GmbH & Co. KG · Bachmühle 2 · D-74673 Mulfingen · Phone +49 7938 81-0 · Fax +49 7938 81-110 · [email protected] · www.ebmpapst.com