ebm-papst W2G110-AG43-01 Скачать руководство пользователя страница 6

Operating instructions

W2G110-AG43-01

Translation of the original operating instructions

4. CONNECTION AND START-UP

4.1 Connecting the mechanical system

CAUTION
Cutting and crushing hazard when removing the device
from the packaging

Blades can be bent
→ Carefully remove the device from its packaging, only

touching the wall ring. Make sure to avoid any shock.

→ Wear safety shoes and cut-resistant safety gloves.

;

Check the device for transport damage. Damaged devices must no
longer be installed.

;

Install the undamaged device according to your application.

4.2 Connecting the electrical system

CAUTION
Electrical voltage

The fan is a built-in component and features no electrically
isolating switch.
→ Only connect the fan to circuits that can be switched off with

an all-pole separating switch.

→ When working on the fan, you must switch off the

installation/machine in which the fan is installed and secure it
from being switched on again.

NOTE
Water penetration into leads or wires

Water enters at the cable end on the customers side and can
damage the device.
→ Make sure that the cable end is connected in a dry

environment.

Operate the device with a safely isolated power pack.

4.2.1 Prerequisites

;

Check whether the data on the type plate agree with the connection
data.

;

Before connecting the device, ensure that the supply voltage matches
the operating voltage of the device.

;

Only use cables designed for current according to the type plate.
For determining the cross-section, follow the basic principles in
accordance with EN 61800-5-1. The protective earth must have a
cross-section equal to or greater than the outer conductor cross-
section.
We recommend the use of 105°C cables. Ensure that the minimum
cable cross-section is at least
AWG26/0.13 mm².

4.2.2 Idle current

Because of the EMC filter integrated for compliance with EMC
limits (interference emission and interference immunity), idle
currents in the mains cable can be measured even when the
motor is at a standstill and the mains voltage is switched on.

4.3 Connection of the cables

External leads are brought out of device.

;

Connect the lines according to your application. When doing so,
observe chapter 4.4 Connection screen.

Item no. 51380-5-9970 · Revision 74353 · Release 2012-08-22 · Page 6 / 9

ebm-papst Mulfingen GmbH & Co. KG · Bachmühle 2 · D-74673 Mulfingen · Phone +49 (0) 7938 81-0 · Fax +49 (0) 7938 81-110 · [email protected] · www.ebmpapst.com

Содержание W2G110-AG43-01

Страница 1: ...Only trained and authorised specialist personnel are permitted to transport unpack assemble operate or maintain the device or to use it in any other manner 1 3 Basic safety rules 1 1 3 Basic safety ru...

Страница 2: ...parts have come to a standstill WARNING Rotating device Long hair loose items of clothing and jewellery could become entangled and pulled into the device You could be injured Do not wear any loose cl...

Страница 3: ...Using the device in the following ways is particularly prohibited and may cause hazards Operating the device with an imbalance e g caused by dirt deposits or icing Moving air that contains abrasive pa...

Страница 4: ...ct drawing All measures have the unit mm 1 Direction of air flow V 2 Connection line 2 x AWG22 300 V red blue Item no 51380 5 9970 Revision 74353 Release 2012 08 22 Page 4 9 ebm papst Mulfingen GmbH C...

Страница 5: ...r protection Reverse polarity and locked rotor protection Product conforming to standard EN 60950 1 For cyclic speed loads note that the rotating parts of the device are designed for maximum one milli...

Страница 6: ...ted in a dry environment Operate the device with a safely isolated power pack 4 2 1 Prerequisites Check whether the data on the type plate agree with the connection data Before connecting the device e...

Страница 7: ...ion assignment 1 1 UN 24V red Power supply 24 V voltage range refer to rating plate residual ripple 3 5 1 2 GND blue Reference mass Item no 51380 5 9970 Revision 74353 Release 2012 08 22 Page 7 9 ebm...

Страница 8: ...AUTION If control voltage is applied or a speed setpoint is stored the motor automatically restarts e g after a power failure Danger of injury Keep out of the danger zone of the device When working on...

Страница 9: ...tal contact for damage and to ensure that it is intact Visual inspection At least every 6 months Repair or replacement of the device Check the device for damage to blades and housing Visual inspection...

Отзывы: