Operating instructions
W2E200-HH82-01
Translation of the original operating instructions
Heating of the motor due to use of a variable frequency drive must be
checked in the application by the customer.
4.3 Connection via terminal strip
4.3.1 Connecting wires to terminals
WARNING
Live terminals and connections even with device
switched off
Electric shock
→ Wait five minutes after disconnecting the voltage at all poles
before opening the device.
;
Insert the wires into the terminals, see
Chapter 4.4 Connection diagram.
NOTE
Damage caused by moisture penetration.
Moisture can penetrate into the terminal box if water is
constantly present at the cable glands.
→ To prevent the constant accumulation of water at the cable
glands, the cable should be routed in a U-shaped loop
wherever possible.# If this is not possible, a drip edge can
be produced by fitting a cable tie directly in front of the cable
gland for example.