ebm-papst W2E142-BB01-11 Скачать руководство пользователя страница 7

Operating instructions

W2E142-BB01-11

Translation of the original operating instructions

Heating-up of the motor when using a variable frequency drive must be
checked by the customer following installation in the end device.

Item no. 10919-5-9970 · ENU · Change 202174 · Approved 2019-01-04 · Page 7 / 10

ebm-papst Mulfingen GmbH & Co. KG · Bachmühle 2 · D-74673 Mulfingen · Phone +49 (0) 7938 81-0 · Fax +49 (0) 7938 81-110 · [email protected] · www.ebmpapst.com

Содержание W2E142-BB01-11

Страница 1: ...ed maintained and otherwise used by suitably qualified trained and authorized technical staff Only authorized specialists are permitted to install the device to carry out a test run and to perform wor...

Страница 2: ...coming into contact with the rotor or the impeller Secure the device against accidental contact Before working on the system machine wait until all parts have come to a standstill WARNING Rotating dev...

Страница 3: ...ing the device in an unbalanced state e g due to dirt deposits or ice formation Resonant operation operation with severe vibration This also includes vibration transmitted to the fan from the customer...

Страница 4: ...CHNICAL DATA 3 1 Product drawing All dimensions in mm 1 2 x flat plug 2 8 x 0 5 mm Item no 10919 5 9970 ENU Change 202174 Approved 2019 01 04 Page 4 10 ebm papst Mulfingen GmbH Co KG Bachm hle 2 D 746...

Страница 5: ...S0 Conformity with standards EN 60335 1 CE Approval EAC With regard to cyclic speed loads note that the rotating parts of the device are designed for a maximum of one million load cycles If you have...

Страница 6: ...he customer end of the cable can damage the device Make sure the end of the cable is connected in a dry environment Only connect the device to circuits that can be switched off with an all pole discon...

Страница 7: ...using a variable frequency drive must be checked by the customer following installation in the end device Item no 10919 5 9970 ENU Change 202174 Approved 2019 01 04 Page 7 10 ebm papst Mulfingen GmbH...

Страница 8: ...inal operating instructions 4 3 Connection diagram Item no 10919 5 9970 ENU Change 202174 Approved 2019 01 04 Page 8 10 ebm papst Mulfingen GmbH Co KG Bachm hle 2 D 74673 Mulfingen Phone 49 0 7938 81...

Страница 9: ...ot perform any repairs on your device Send the device to ebm papst for repair or replacement WARNING Live terminals and connections even with device switched off Electric shock Wait five minutes after...

Страница 10: ...regulations with regard to the disposal of products or waste occurring in the various phases of the life cycle The corresponding disposal standards are also to be heeded 5 3 2 Disassembly Disassembly...