ebm-papst W2D250-CI14-09 Скачать руководство пользователя страница 5

Operating instructions

W2D250-CI14-09

Translation of the original operating instructions

3.2 Nominal data

Motor

M2D068-CF

Phase

3~

3~

3~

3~

Nominal voltage / VAC

208

220

220

230

Wiring

Δ

Δ

Δ

Δ

Frequency / Hz

60

50

60

50

Method of obtaining
data

fa

fa

fa

fa

Valid for approval/
standard

CE

CE

CE

CE

Speed (rpm) / min

-1

2350

2370

2440

2460

Power consumption / W

128

102

135

110

Current draw / A

0.40

0.33

0.40

0.33

Max. back pressure / Pa

84

93

93

100

Min. ambient
temperature / °C

-25

-25

-25

-25

Max. ambient
temperature / °C

60

80

60

80

Phase

3~

3~

3~

3~

Nominal voltage / VAC

230

360

380

380

Wiring

Δ

Y

Y

Y

Frequency / Hz

60

60

50

60

Method of obtaining
data

fa

fa

fa

fa

Valid for approval/
standard

CE

CE

CE

CE

Speed (rpm) / min

-1

2580

2350

2370

2440

Power consumption / W

140

128

102

135

Current draw / A

0.38

0.23

0.19

0.23

Max. back pressure / Pa

100

84

93

93

Min. ambient
temperature / °C

-25

-25

-25

-25

Max. ambient
temperature / °C

60

60

80

60

Phase

3~

3~

3~

3~

Nominal voltage / VAC

400

400

415

460

Wiring

Y

Y

Y

Y

Frequency / Hz

50

60

50

60

Method of obtaining
data

fa

fa

fa

fa

Valid for approval/
standard

CE

CE

CE

CE

Speed (rpm) / min

-1

2460

2580

2500

2750

Power consumption / W

110

140

115

160

Current draw / A

0.19

0.22

0.20

0.23

Max. back pressure / Pa

100

100

105

120

Min. ambient
temperature / °C

-25

-25

-25

-25

Max. ambient
temperature / °C

80

60

80

60

Phase

3~

Nominal voltage / VAC

480

Wiring

Y

Frequency / Hz

60

Method of obtaining
data

fa

Valid for approval/
standard

CE

Speed (rpm) / min

-1

2680

Power consumption / W

170

Current draw / A

0.23

Max. back pressure / Pa

110

Min. ambient
temperature / °C

-25

Max. ambient
temperature / °C

65

ml = Max. load · me = Max. efficiency · fa = Free air

cs = Customer specification · ce = Customer equipment

Subject to change

3.3 Technical description

Weight

3.3 kg

Size

250 mm

Motor size

68

Rotor surface

Painted black

Terminal box material

PP plastic

Blade material

Sheet steel, painted black

Fan housing material

Sheet steel, pre-galvanized, primed and
coated with black plastic (RAL 9005)

Guard grille material

Steel, coated with black plastic (RAL
9005)

Number of blades

9

Airflow direction

A

Direction of rotation

Counterclockwise, viewed toward rotor

Degree of protection

IP44; installation- and position-dependent
as per EN 60034-5

Insulation class

"F"

Moisture (F) /
Environmental (H)
protection class

H1+

Installation position

Shaft horizontal or rotor on bottom; rotor
on top on request

Condensation
drainage holes

On rotor side

Mode

S1

Motor bearing

Ball bearing

Touch current
according to IEC
60990 (measuring
circuit Fig. 4, TN
system)

< 0.75 mA

Electrical hookup

Terminal box

with cable

Axial

Protection class

I (with customer connection of protective
earth)

Conformity with
standards

EN 60034-1; EN 60204-1; CE

Approval

UL 1004-1; CSA C22.2 No. 100

Item no. 12750-5-9970 · ENU · Change 212939 · Approved 2020-08-06 · Page 5 / 12

ebm-papst Mulfingen GmbH & Co. KG · Bachmühle 2 · D-74673 Mulfingen · Phone +49 (0) 7938 81-0 · Fax +49 (0) 7938 81-110 · [email protected] · www.ebmpapst.com

Содержание W2D250-CI14-09

Страница 1: ...itably qualified trained and authorized technical staff Only authorized specialists are permitted to install the device to carry out a test run and to perform work on the electrical installation 1 3 B...

Страница 2: ...e Long hair and dangling items of clothing jewelry and the like can become entangled and be pulled into the device Injuries can result Do not wear any loose fitting or dangling clothing or jewelry whi...

Страница 3: ...be hazardous Operating the device in an unbalanced state e g due to dirt deposits or ice formation Resonant operation operation with severe vibration This also includes vibration transmitted to the fa...

Страница 4: ...in mm 1 Direction of air flow A 2 Tightening torque 1 5 0 2 Nm 3 Cable diameter min 4 mm max 10 mm tightening torque 2 5 0 4 Nm Item no 12750 5 9970 ENU Change 212939 Approved 2020 08 06 Page 4 12 eb...

Страница 5: ...od of obtaining data fa Valid for approval standard CE Speed rpm min 1 2680 Power consumption W 170 Current draw A 0 23 Max back pressure Pa 110 Min ambient temperature C 25 Max ambient temperature C...

Страница 6: ...ng Strictly avoid shocks Wear safety shoes and cut resistant safety gloves NOTE Damage to the device from vibration Bearing damage shorter service life The fan must not be subjected to force or excess...

Страница 7: ...e frequency drives an all pole sine filter protects the motor against high voltage transients that can destroy the coil insulation system and against harmful bearing currents Heating up of the motor w...

Страница 8: ...3 4 Motor protection WARNING Device has no overheating protection The device is supplied without any automatic overheating protection The device can become hot and catch fire For the version without t...

Страница 9: ...two phases Three phase motor Delta connection Y Star connection L1 U1 black L2 V1 blue L3 W1 brown U2 green V2 white W2 yellow PE green yellow Item no 12750 5 9970 ENU Change 212939 Approved 2020 08 0...

Страница 10: ...st be ensured over the entire speed control range Severe vibration can arise for instance from inexpert handling transportation damage and resultant imbalance or be caused by component or structural r...

Страница 11: ...d contact ebm papst Adapt the maintenance intervals to the actual level of dust exposure 5 2 Safety inspection What to check How to check How often What action Contact protection cover for intactness...

Страница 12: ...lating materials Cables and wires Electronic scrap e g circuit boards Only ferrite magnets and not rare earth magnets are used in external rotor motors from ebm papst Mulfingen GmbH Co KG Ferrite magn...