3.2 Nominal data

Motor

M1G055-BD

Phase

1~

Nominal voltage / VAC

115

Frequency / Hz

50/60

Method of obtaining
data

ml

Speed (rpm) / min

-1

1300

Power consumption / W

10

Current draw / A

0.15

Min. ambient
temperature / °C

-30

Max. ambient
temperature / °C

50

ml = Max. load · me = Max. efficiency · fa = Free air

cs = Customer specification · ce = Customer equipment

Subject to change

3.3 Technical description

Weight

1 kg

Fan size

200 mm

Rotor surface

Painted black

Blade material

Sheet steel, painted black

Fan housing material

PP plastic

Number of blades

5

Airflow direction

"V"

Degree of protection

IP54

Insulation class

"B"

Moisture (F) /
Environmental (H)
protection class

H1

Installation position

Any

Condensation
drainage holes

None

Mode

S1

Motor bearing

Ball bearing

Technical features

- ESM+ expandable with plug-in module
- Soft start
- Thermal overload protection for motor

Motor protection

Thermal overload protector (TOP)
internally connected

with cable

Lateral

Protection class

II

Conformity with
standards

EN 60335-1; EN 60335-2-24; EN 60335-
2-80; EN 60335-2-89

Approval

UL 1004-3; CSA C22.2 No. 77

With regard to cyclic speed loads, note that the rotating parts of
the device are designed for a maximum of one million load
cycles. If you have special questions, consult ebm-papst for
support.

Information on surface quality

The surfaces of the products conform to the generally applicable industrial
standard. The surface quality may change during the production period.
This has no effect on strength, dimensional stability and dimensional
accuracy.
The color pigments in the paints used perceptibly react to UV light over
the course of time. This does not however in any way affect the
technical properties of the products. The product is to be protected against
UV radiation to prevent the formation of patches and fading. Changes in
color are not a reason for complaint and are not covered by the warranty.

3.4 Mounting data

For screw clearance, see Chapter 3.1 Product drawing

;

Secure the screws against unintentional loosening (e.g. use self-
locking screws).

Strength class of
screws

8.8

Any further mounting data required can be taken from the product drawing.

3.5 Transport and storage conditions

;

Use the device in accordance with its degree of protection.

Max. permitted
ambient temp. for
motor (transport/
storage)

+ 80 °C

Min. permitted
ambient temp. for
motor (transport/
storage)

- 40 °C

Item no. 54829-5-9970 · ENU · Change 89285 · Approved 2016-10-05 · Page 5 / 11

ebm-papst Mulfingen GmbH & Co. KG · Bachmühle 2 · D-74673 Mulfingen · Phone +49 (0) 7938 81-0 · Fax +49 (0) 7938 81-110 · [email protected] · www.ebmpapst.com

Downloaded from

Arrow.com.

Downloaded from

Arrow.com.

Downloaded from

Arrow.com.

Downloaded from

Arrow.com.

Downloaded from

Arrow.com.

Содержание W1G200-EA95-68

Страница 1: ...maintained and otherwise used by suitably qualified trained and authorized technical staff Only authorized specialists are permitted to install the device to carry out a test run and to perform work...

Страница 2: ...ent Verify that the entire setup is EMC compliant 1 7 Mechanical movement DANGER Rotating device Risk of injury to body parts coming into contact with the rotor or the impeller Secure the device again...

Страница 3: ...lowing ways is prohibited and could be hazardous Operating the device in an unbalanced state e g due to dirt deposits or ice formation Resonant operation operation with severe vibration This also incl...

Страница 4: ...tor housing compatible with EMF Corporation P 2 1 075 2x plug contact tyco 61013 2 Item no 54829 5 9970 ENU Change 89285 Approved 2016 10 05 Page 4 11 ebm papst Mulfingen GmbH Co KG Bachm hle 2 D 7467...

Страница 5: ...ou have special questions consult ebm papst for support Information on surface quality The surfaces of the products conform to the generally applicable industrial standard The surface quality may chan...

Страница 6: ...ith an all pole disconnection switch 4 2 1 Requirements Check whether the information on the nameplate matches the connection data Before connecting the device make sure the power supply matches the d...

Страница 7: ...be routed downward NOTE Cable routing is to be performed accordingly if use is made of the ESM plug in module to connect the fan Item no 54829 5 9970 ENU Change 89285 Approved 2016 10 05 Page 7 11 ebm...

Страница 8: ...ved 2016 10 05 Page 8 11 ebm papst Mulfingen GmbH Co KG Bachm hle 2 D 74673 Mulfingen Phone 49 0 7938 81 0 Fax 49 0 7938 81 110 info1 de ebmpapst com www ebmpapst com Downloaded from Arrow com Downloa...

Страница 9: ...bed in the table Fault Safety feature description function Rotor position detection error An automatic restart follows Blocked rotor After the blockage is removed the motor restarts automatically Moto...

Страница 10: ...iteria The following section contains recommendations for ecological disposal of the product and its components 6 3 1 Country specific legal requirements NOTE Country specific legal requirements Alway...

Страница 11: ...e 89285 Approved 2016 10 05 Page 11 11 ebm papst Mulfingen GmbH Co KG Bachm hle 2 D 74673 Mulfingen Phone 49 0 7938 81 0 Fax 49 0 7938 81 110 info1 de ebmpapst com www ebmpapst com Downloaded from Arr...

Отзывы: