3.2 Nominal data

Motor

M1G055-BD

Phase

1~

1~

Nominal voltage / VAC

230

230

Frequency / Hz

50/60

50/60

Method of obtaining
data

ml

Speed (rpm) / min

-1

2200

1500

Power consumption / W

28.1

-

Current draw / A

0.21

Min. ambient
temperature / °C

-30

-30

Max. ambient
temperature / °C

50

50

ml = Max. load · me = Max. efficiency · fa = Free air

cs = Customer specification · ce = Customer equipment

Subject to change

3.3 Technical description

Weight

1 kg

Fan size

200 mm

Rotor surface

Painted black

Blade material

Sheet steel, painted black

Fan housing material

PP plastic

Number of blades

5

Direction of rotation

"V"

Degree of protection

IP54

Insulation class

"B"

Moisture (F) /
Environmental (H)
protection class

H1

Installation position

Shaft horizontal or rotor on bottom; rotor
on top on request

Condensation
drainage holes

On rotor side

Mode

S1

Motor bearing

Ball bearing

Technical features

- Speed selection max./min.
- Soft start
- Thermal overload protection for motor

with cable

Lateral

Protection class

II

Conformity with
standards

EN 60335-1; EN 60335-1; EN 60335-2-
24; EN 60335-2-80; EN 60335-2-89; CE

Approval

CCC;VDE; UL

With regard to cyclic speed loads, note that the rotating parts of
the device are designed for a maximum of one million load
cycles. If you have special questions, consult ebm-papst for
support.

3.4 Mounting data

For screw clearance, see Chapter 3.1 Product drawing

;

Secure the screws against unintentional loosening (e.g. use self-
locking screws).

Strength class of
screws

8.8

Any further mounting data required can be taken from the product drawing.

3.5 Transport and storage conditions

;

Use the device in accordance with its degree of protection.

Max. permitted
ambient temp. for
motor (transport/
storage)

+80 °C

Min. permitted
ambient temp. for
motor (transport/
storage)

-40 °C

3.6 Electromagnetic compatibility

EMC immunity to
interference

According to EN 61000-6-2 (industrial
environment)

EMC circuit feedback

According to EN 61000-3-2/3

EMC interference
emission

According to EN 61000-6-3 (household
environment)

Page 5 / 10              Revision  0

Содержание W1G200-EA91-45

Страница 1: ...sed by suitably qualified trained and authorized technical staff Only authorized specialists are permitted to install the device to carry out a test run and to perform work on the electrical installat...

Страница 2: ...e working on rotating parts Protect long hair with a cap 1 8 Emissions WARNING Depending on the installation and operating conditions the sound pressure level may exceed 70 dB A Risk of noise induced...

Страница 3: ...EA91 45 Translation of the original operating instructions Operation with completely or partially disassembled or manipulated protective devices In addition all applications not listed among the inten...

Страница 4: ...tructions W1G200 EA91 45 Translation of the original operating instructions 3 TECHNICAL DATA 3 1 Product drawing All dimensions in mm 1 Direction of air flow V 2 Cable AWG20 3x crimped splices Page 4...

Страница 5: ...election max min Soft start Thermal overload protection for motor with cable Lateral Protection class II Conformity with standards EN 60335 1 EN 60335 1 EN 60335 2 24 EN 60335 2 80 EN 60335 2 89 CE Ap...

Страница 6: ...nvironment Only connect the device to circuits that can be switched off with an all pole disconnection switch 4 2 1 Requirements Check whether the data on the nameplate match the connection data Befor...

Страница 7: ...Operating instructions W1G200 EA91 45 Translation of the original operating instructions 4 4 Connection diagram Drawing preliminary Page 7 10 Revision 0...

Страница 8: ...ection error An automatic restart follows Blocked rotor After the blockage is removed the motor restarts automatically 6 MAINTENANCE MALFUNCTIONS POSSIBLE CAUSES AND REMEDIES Do not perform any repair...

Страница 9: ...nd rigorously implemented around the world on the basis of German standards Right from the development stage ecological design technical safety and health protection are fixed criteria The following s...

Страница 10: ...EA91 45 Translation of the original operating instructions Dispose of electronic components employing the proper procedures for electronic scrap Please contact ebm papst for any other questions on di...

Отзывы: