Operating instructions
S8E630-AN01-01
Translation of the original operating instructions
3.2 Nominal data
Motor
M8E110-GF
Phase
1~
1~
Nominal voltage / VAC
230
230
Frequency / Hz
50
60
Type of data definition
ml
ml
Valid for approval /
standard
CE
CE
Speed / min
-1
670
710
Power input / W
340
460
Current draw / A
1.72
2.12
Motor capacitor / µF
7
7
Capacitor voltage / VDB
450
450
Max. back pressure / Pa
60
75
Min. ambient
temperature / °C
-40
-40
Max. ambient
temperature / °C
65
55
Starting current / A
5.6
4.7
ml = max. load · me = max. efficiency · fa = running at free air
cs = customer specs · cu = customer unit
Subject to alterations
3.3 Technical features
Mass
17 kg
Size
630 mm
Surface of rotor
Coated in black
Material of terminal box
ABS plastic, black
Material of blades
Press-fitted sheet steel blank, sprayed
with PP plastic
Material of guard grille
Steel, phosphated and coated in black
plastic
Number of blades
5
Blade angle
-5°
Direction of air flow
"V"
Direction of rotation
Counter-clockwise, seen on rotor
Type of protection
IP 54
Insulation class
"F"
Humidity class
F4-1
Mounting position
Shaft horizontal or rotor on bottom; rotor
on top on request
Condensate discharge
holes
Rotor-side
Operation mode
S1
Motor bearing
Ball bearing
Touch current acc.
IEC 60990 (measuring
network Fig. 4, TN
system)
<= 3.5 mA
Electrical leads
Via terminal box, integrated capacitor
connected via terminal box
Motor protection
Thermal overload protector (TOP)
brought out
Cable exit
Axial
Protection class
I (if protective earth is connected by
customer)
Product conforming
to standard
EN 61800-5-1; CE
Approval
GOST; VDE; UL 1004-1; CSA C22.2
Nr.100
For cyclic speed loads, note that the rotating parts of the device
are designed for maximum one million load cycles. If you have
specific questions, contact ebm-papst for support.
3.4 Mounting data
;
Secure the mounting screws against accidentally coming loose (e.g.
by using self-locking screws).
Strength class for
mounting screws
8.8
You can obtain additional mounting data from the product drawing if
necessary.
3.5 Transport and storage conditions
;
Use the device in accordance with its protection type.
Max. permissible
ambient motor temp.
(transp./ storage)
+ 80 °C
Min. permissible
ambient motor temp.
(transp./storage)
- 40 °C
Item no. 10933-5-9970 · Revision 71516 · Release 2010-11-02 · Page 5 / 10
ebm-papst Mulfingen GmbH & Co. KG · Bachmühle 2 · D-74673 Mulfingen · Phone +49 (0) 7938 81-0 · Fax +49 (0) 7938 81-110 · [email protected] · www.ebmpapst.com