ebm-papst S4E450-AP01-11 Скачать руководство пользователя страница 8

Operating instructions

S4E450-AP01-11

Translation of the original operating instructions

4.4 Connection diagram

L

= U1 = blue

Z

brown

N

= U2 = black

PE

green/yellow

Item no. 12347-5-9970 · ENU · Change 205173 · Approved 2019-11-20 · Page 8 / 11

ebm-papst Mulfingen GmbH & Co. KG · Bachmühle 2 · D-74673 Mulfingen · Phone +49 (0) 7938 81-0 · Fax +49 (0) 7938 81-110 · [email protected] · www.ebmpapst.com

Частное

 

предприятие

 "

Юдилен

-

Холод

"  ||  +375296803378  ||  https://

купизапчасть

.

бел

  ||  

Минская

 

обл

., 

Минский

 

р

-

н

Щомыслицкий

 

с

/

с

, 92/4

Частное

 

предприятие

 "

Юдилен

-

Холод

"  ||  +375296803378  ||  https://

купизапчасть

.

бел

  ||  

Минская

 

обл

., 

Минский

 

р

-

н

Щомыслицкий

 

с

/

с

, 92/4

Содержание S4E450-AP01-11

Страница 1: ...ized specialists are permitted to install the device to carry out a test run and to perform work on the electrical installation 1 3 Basic safety rules 1 1 3 Basic safety rules The safety hazards assoc...

Страница 2: ...nt DANGER Rotating device Risk of injury to body parts coming into contact with the rotor or the impeller Secure the device against accidental contact Before working on the system machine wait until a...

Страница 3: ...to dirt deposits or ice formation Resonant operation operation with severe vibration This also includes vibration transmitted to the fan from the customer installation Operation in medical equipment...

Страница 4: ...r flow V 2 Tightening torque 1 5 0 2 Nm 3 Cable diameter min 6 mm max 12 mm tightening torque 1 3 0 2 Nm Item no 12347 5 9970 ENU Change 205173 Approved 2019 11 20 Page 4 11 ebm papst Mulfingen GmbH C...

Страница 5: ...rial ABS plastic Blade material Sheet steel galvanized Guard grille material Steel coated with black plastic RAL 9005 Number of blades 5 Airflow direction V Direction of rotation Counterclockwise view...

Страница 6: ...aulty insulation Risk of fatal injury from electric shock Use only cables that meet the specified installation regulations for voltage current insulation material capacity etc Route cables so that the...

Страница 7: ...nal box 4 3 1 Preparing cables for connection Only strip the cable as far as necessary ensuring that the cable gland is sealed and there is no strain on the connections For tightening torques see Chap...

Страница 8: ...ram L U1 blue Z brown N U2 black PE green yellow Item no 12347 5 9970 ENU Change 205173 Approved 2019 11 20 Page 8 11 ebm papst Mulfingen GmbH Co KG Bachm hle 2 D 74673 Mulfingen Phone 49 0 7938 81 0...

Страница 9: ...e Severe vibration can arise for instance from inexpert handling transportation damage and resultant imbalance or be caused by component or structural resonance Speed ranges with excessively high vibr...

Страница 10: ...eed so that any water that has ingressed can evaporate If cleaning does not eliminate vibrations the fan may need to be rebalanced To have it rebalanced contact ebm papst The fan is equipped with main...

Страница 11: ...erally considered to be fully recyclable Separate the components for recycling into the following categories Steel and iron Aluminum Non ferrous metal e g motor windings Plastics particularly with bro...

Отзывы: