3.2 Nominal data

Motor

M4E068-DF

Phase

1~

1~

Nominal voltage / VAC

230

230

Frequency / Hz

50

60

Type of data definition

fa

fa

Valid for approval /
standard

CE

CE

Speed (rpm) / min

-1

1370

1530

Power input / W

95

135

Current draw / A

0.42

0.6

Motor capacitor / µF

3

3

Capacitor voltage / VDB

400

400

Max. back pressure / Pa

75

65

Min. ambient
temperature / °C

-40

-40

Max. ambient
temperature / °C

40

40

ml = Max. load · me = Max. efficiency · fa = Running at free air

cs = Customer specs · cu = Customer unit

Subject to alterations

3.3 Technical features

Mass

3.79 kg

Size

315 mm

Motor size

68

Surface of rotor

Coated in black

Material of blades

Sheet steel, coated in black

Number of blades

5

Direction of air flow

V

Direction of rotation

Counter-clockwise, seen on rotor

Type of protection

IP44

Insulation class

"B"

Humidity (F) /
environmental
protection class (H)

H1+

Mounting position

Shaft horizontal or rotor on bottom; rotor
on top on request

Condensation
drainage holes

Rotor-side

Operation mode

S1

Motor bearing

Ball bearing with anti-freezing grease

Touch current acc.
IEC 60990 (measuring
network Fig. 4, TN
system)

< 0.75 mA

Electrical connection

Terminal box; Via terminal box, capacitor
integrated and connected

Motor protection

Thermal overload protector (TOP) wired
internally

Cable exit

Axial

Protection class

I (if protective earth is connected by
customer)

Motor capacitor
according to EN 60252-
1 in safety protection
class

S0

Product conforming
to standard

EN 60335-1; CE

Approval

CCC; EAC

For cyclic speed loads, note that the rotating parts of the device
are designed for maximum one million load cycles. If you have
specific questions, contact ebm-papst for support.

;

Use the device in accordance with its protection type.

Notes on surface quality

The surfaces of the products conform to the generally applicable industrial
standard. The surface quality may vary during the production period.
Strength, dimensional stability and dimensional accuracy are not affected
by this.
The colour pigments of the paints used react perceptibly to UV light over
the course of time. To prevent the formation of patches and fading, the
product is to be protected against UV radiation. Changes in colour are
not a reason for complaint and are not covered by the warranty. UV
radiation in the frequency range and the intensity of natural solar radiation
has no effect on the technical properties of the products.

3.4 Mounting data

Any further mounting data required can be taken from the product
drawing or Section chapter 4.1 Connecting the mechanical system.

Strength class for
mounting screws

8.8

;

Secure the mounting screws against accidentally coming loose (e.g.
by using self-locking screws).

3.5 Transport and storage conditions

Max. permissible
ambient motor temp.
(transp./ storage)

+ 70 °C

Min. permissible
ambient motor temp.
(transp./storage)

- 40 °C

Item no. 11062-5-9970 · ENG · Revision 206792 · Release 2019-11-18 · Page 5 / 11

ebm-papst Mulfingen GmbH & Co. KG · Bachmühle 2 · D-74673 Mulfingen · Phone +49 (0) 7938 81-0 · Fax +49 (0) 7938 81-110 · [email protected] · www.ebmpapst.com

Содержание S4E315-AC08-07

Страница 1: ... trained and authorised technical staff Only authorised specialists are permitted to install the device to carry out a test run and to perform work on the electrical installation 1 3 Basic safety rules 1 1 3 Basic safety rules Any safety hazards stemming from the device must be re evaluated once it is installed in the end device The local industrial safety regulations must always be observed when ...

Страница 2: ...tem machine wait until all parts have come to a standstill WARNING Rotating device Long hair dangling items of clothing jewellery and similar items can become entangled and be pulled into the device Risk of injury Do not wear any loose fitting or dangling clothing or jewellery while working on rotating parts Protect long hair with a cap 1 7 Emission WARNING Depending on the installation and operat...

Страница 3: ...nce e g caused by dirt deposits or icing Resonance mode operation with heavy vibrations These also include vibrations that are transmitted from the customer system to the fan Operation in medical equipment with a life sustaining or lifesaving function Moving solids content in flow medium Painting the device Connections e g screws coming loose during operation Opening the terminal box during operat...

Страница 4: ...he unit mm 1 Direction of air flow V 2 Tightening torque 1 5 0 2 Nm 3 Cable diameter min 4 mm max 8 mm tightening torque 1 3 Nm 0 2 Nm Item no 11062 5 9970 ENG Revision 206792 Release 2019 11 18 Page 4 11 ebm papst Mulfingen GmbH Co KG Bachmühle 2 D 74673 Mulfingen Phone 49 0 7938 81 0 Fax 49 0 7938 81 110 info1 de ebmpapst com www ebmpapst com ...

Страница 5: ... 1 in safety protection class S0 Product conforming to standard EN 60335 1 CE Approval CCC EAC For cyclic speed loads note that the rotating parts of the device are designed for maximum one million load cycles If you have specific questions contact ebm papst for support Use the device in accordance with its protection type Notes on surface quality The surfaces of the products conform to the genera...

Страница 6: ...chine in which the fan is installed and secure it from being switched on again CAUTION Electric shock Electric voltage on the metal part Use the device only with the cable guard and terminal box provided for this purpose NOTE Water penetration into leads or wires Water enters at the cable end on the customers side and can damage the device Make sure that the cable end is connected in a dry environ...

Страница 7: ...into the terminal box First connect the PE protective earth connection Connect the lines to the corresponding terminals Use a screwdriver to do so During the connection work ensure that no cables splice off The terminal strip is equipped with a penetration prevention device Insert the strands until they meet resistance Seal the terminal box 4 3 3 Cable routing No water may penetrate along the cabl...

Страница 8: ...tions 4 4 Connection screen L U1 blue Z brown N U2 black PE green yellow Item no 11062 5 9970 ENG Revision 206792 Release 2019 11 18 Page 8 11 ebm papst Mulfingen GmbH Co KG Bachmühle 2 D 74673 Mulfingen Phone 49 0 7938 81 0 Fax 49 0 7938 81 110 info1 de ebmpapst com www ebmpapst com ...

Страница 9: ... main switch for the supply line When disconnecting be sure to disconnect the earth wire connection last 5 MAINTENANCE MALFUNCTIONS POSSIBLE CAUSES AND REMEDIES Do not perform any repairs on your device Return the device to ebm papst for repair or replacement WARNING Terminals and connections have voltage even with a unit that is shut off Electric shock Wait five minutes after disconnecting the vo...

Страница 10: ...rvals to the dust pollution occurring 5 2 Safety test What has to be tested How to test Frequency Which measure Check the protective casing against accidental contact for damage and to ensure that it is intact Visual inspection At least every 6 months Repair or replacement of the device Check the device for damage to blades and housing Visual inspection At least every 6 months Replacement of the d...

Страница 11: ...inium Non ferrous metal e g motor windings Plastics particularly with brominated flame retardants in accordance with marking Insulating materials Cables and wires Electronic scrap e g circuit boards Only ferrite magnets and not rare earth magnets are used in external rotor motors from ebm papst Mulfingen GmbH Co KG Ferrite magnets can be disposed of in the same way as normal iron and steel Electri...

Отзывы: