Operating instructions
S3G500-AE33-01
Translation of the original operating instructions
3.2 Nominal data
Motor
M3G112-GA
Phase
3~
Nominal voltage / VAC
400
Nominal voltage
range / VAC
380 .. 480
Frequency / Hz
50/60
Type of data definition
ml
Speed / min
-1
1440
Power input / W
1050
Current draw / A
1.9
Min. ambient
temperature / °C
-25
Max. ambient
temperature / °C
60
ml = max. load · me = max. efficiency · fa = running at free air
cs = customer specs · cu = customer unit
Subject to alterations
3.3 Data according to ErP directive
Installation category
A
Efficiency category
Static
Variable speed drive
Yes
Specific ratio
*
1.00
*
Specific ratio = 1 + p
fs
/ 100 000 Pa
Actual
Request
2013
Request
2015
Overall efficiency η
es
37.4
29.8
33.8
Efficiency grade N
43.6
36
40
Power input P
ed
/ kW
1.03
Air flow q
v
/ m³/h
6540
Pressure increase total p
sf
/ Pa
196
Speed n / min
-1
1455
Data established at point of optimum efficiency
3.4 Technical features
Mass
12.4 kg
Size
500 mm
Surface of rotor
Cast in PA plastic
Material of electronics
housing
Die-cast aluminium, coated in black
Material of blades
Press-fitted sheet steel blank, sprayed
with PP plastic
Material of guard grille
Steel, phosphated and coated in black
plastic
Number of blades
5
Direction of rotation
"V"
Type of protection
IP 54
Insulation class
"B"
Humidity class
F4-1
Mounting position
Shaft horizontal or rotor on bottom; rotor
on top on request
Condensate discharge
holes
Rotor-side
Operation mode
S1
Motor bearing
Ball bearing
Technical features
- PFC, passive
- Control input 0-10 VDC / PWM
- Over-temperature protected
electronics / motor
- Alarm relay
- Integrated PID controller
- Input for sensor 0-10 V and 4-20 mA
- Output for slave 0-10 V max. 3 mA
- Output 20 VDC (+25 %/-10 %) max.
50 mA
- Output 10 VDC (+/-3 %) max. 10 mA
- RS485 ebmBUS
- Motor current limit
- Soft start
- Line undervoltage / phase failure
detection
Touch current acc.
IEC 60990 (measuring
network Fig. 4, TN
system)
<= 3.5 mA
Electrical leads
Via terminal box
Motor protection
Thermal overload protector (TOP) wired
internally
Protection class
I (if protective earth is connected by
customer)
For cyclic speed loads, note that the rotating parts of the device
are designed for maximum one million load cycles. If you have
specific questions, contact ebm-papst for support.
3.5 Mounting data
;
Secure the mounting screws against accidentally coming loose (e.g.
by using self-locking screws).
Strength class for
mounting screws
8.8
You can obtain additional mounting data from the product drawing if
necessary.
3.6 Transport and storage conditions
;
Use the device in accordance with its protection type.
Max. permissible
ambient motor temp.
(transp./ storage)
+80 °C
Min. permissible
ambient motor temp.
(transp./storage)
-40 °C
3.7 Electromagnetic compatibility
EMC interference
immunity
Acc. to EN 61000-6-2
EMC harmonics
Acc. to EN 61000-3-2/3
EMC interference
emission
Acc. to EN 61000-6-3
Item no. 50344-5-9970 · Revision 68161 · Release 2009-09-09 · Page 5 / 12
ebm-papst Mulfingen GmbH & Co. KG · Bachmühle 2 · D-74673 Mulfingen · Phone +49 (0) 7938 81-0 · Fax +49 (0) 7938 81-110 · [email protected] · www.ebmpapst.com