Operating instructions
R4E355-AG04-13
Translation of the original operating instructions
3.2 Nominal data
Motor
M4E074-GA
Phase
1~
1~
1~
Nominal voltage / VAC
115
115
115
Frequency / Hz
50
60
60
Method of obtaining
data
fa
fa
fa
Valid for approval/
standard
CE
CE
UL 2111
Speed (rpm) / min
-1
1430
1680
1680
Power consumption / W
210
350
360
Current draw / A
2.0
3.1
3.05
Capacitor / µF
25
30
30
Capacitor voltage / VDB
220
220
220
Capacitor standard
S2 (CE)
S2 (CE)
UL
Min. back pressure / Pa
0
0
Min. ambient
temperature / °C
-25
-25
-25
Max. ambient
temperature / °C
40
40
40
Starting current / A
5.5
11
ml = Max. load · me = Max. efficiency · fa = Free air
cs = Customer specification · ce = Customer equipment
Subject to change
3.3 Technical description
Weight
5.4 kg
Fan size
355 mm
Rotor surface
Painted black
Impeller material
PP plastic
Number of blades
6
Direction of rotation
Clockwise, viewed toward rotor
Degree of protection
IP44; installation- and position-dependent
as per EN 60034-5
Insulation class
"F"
Moisture (F) /
Environmental (H)
protection class
H0+
Installation position
Shaft horizontal or rotor on bottom; rotor
on top on request
Condensation
drainage holes
On rotor side
Mode
S1
Motor bearing
Ball bearing
Touch current
according to IEC
60990 (measuring
circuit Fig. 4, TN
system)
< 0.75 mA
Motor protection
Thermal overload protector (TOP)
internally connected
with cable
Axial
Protection class
I (with customer connection of protective
earth)
Conformity with
standards
EN 60335-1; CE
Approval
CSA C22.2 No. 100; UL 1004-1
With regard to cyclic speed loads, note that the rotating parts of
the device are designed for a maximum of one million load
cycles. If you have special questions, consult ebm-papst for
support.
3.4 Mounting data
For screw clearance, see Chapter 3.1 Product drawing
;
Secure the screws against unintentional loosening (e.g. use self-
locking screws).
Strength class of
screws
8.8
Any further mounting data required can be taken from the product drawing.
3.5 Transport and storage conditions
;
Use the device in accordance with its degree of protection.
Max. permitted
ambient temp. for
motor (transport/
storage)
+ 80 °C
Min. permitted
ambient temp. for
motor (transport/
storage)
- 40 °C
4. CONNECTION AND STARTUP
4.1 Mechanical connection
CAUTION
Cutting and crushing hazard when removing fan from
packaging
→ Carefully remove the device from its packaging, by the fan
impeller. Strictly avoid shocks.
→ Wear safety shoes and cut-resistant safety gloves.
NOTE
Damage to the device from vibration
Bearing damage, shorter service life
→ The fan must not be subjected to force or excessive vibration
from sections of the installation. #If the fan is connected to air
ducts, the connection should be isolated from vibration, e.g.
using compensators or similar elements. #Ensure stress-free
attachment of the fan to the substructure.
;
Check the device for transport damage. Damaged devices are not to
be installed.
;
Install the undamaged device in accordance with your application.
CAUTION
Possible damage to the device
If the device slips during installation, serious damage can result.
→ Ensure that the device is securely positioned at its place of
installation until all fastening screws have been tightened.
Item no. 11853-5-9970 · ENU · Change 89188 · Approved 2016-08-26 · Page 5 / 9
ebm-papst Mulfingen GmbH & Co. KG · Bachmühle 2 · D-74673 Mulfingen · Phone +49 (0) 7938 81-0 · Fax +49 (0) 7938 81-110 · [email protected] · www.ebmpapst.com