background image

Operating instructions

R4D310-AS18-01

Translation of the original operating instructions

3.2 Nominal data

Motor

M4D068-EC

Phase

3~

3~

3~

3~

Nominal voltage / VAC

230

230

400

400

Connection

Δ

Δ

Y

Y

Frequency / Hz

50

60

50

60

Type of data definition

fa

fa

fa

fa

Valid for approval /
standard

CE

CE

CE

CE

Speed / min

-1

1400

1600

1400

1600

Power input / W

110

150

110

150

Current draw / A

0.55

0.52

0.32

0.3

Min. back pressure / Pa

0

0

0

0

Min. ambient
temperature / °C

-25

-25

-25

-25

Max. ambient
temperature / °C

65

55

65

55

ml = max. load · me = max. efficiency · fa = running at free air

cs = customer specs · cu = customer unit

Subject to alterations

3.3 Data according to ErP directive

Installation category

A

Efficiency category

Static

Variable speed drive

No

Specific ratio

*

1.00

*

Specific ratio = 1 + p

fs

/ 100 000 Pa

Actual

Request
2013

Request
2015

Overall efficiency η

es

43

38.5

42.5

Efficiency grade N

62.5

58

62

Power input P

e

/ kW

0.14

Air flow q

v

/ m³/h

1465

Pressure increase total p

sf

/ Pa

151

Speed n / min

-1

1350

Data established at point of optimum efficiency

3.4 Technical features

Mass

3.7 kg

Size

310 mm

Surface of rotor

Coated in black

Material of impeller

Aluminium sheet

Number of blades

6

Direction of rotation

Clockwise, seen on rotor

Type of protection

IP 44; Depending on installation and
position as per EN 60034-5

Insulation class

"B"

Humidity class

F1-2

Mounting position

Any

Condensate discharge
holes

Rotor-side

Operation mode

S1

Motor bearing

Ball bearing

Touch current acc.
IEC 60990 (measuring
network Fig. 4, TN
system)

< 0.75 mA

Motor protection

Thermal overload protector (TOP)
brought out

Cable exit

Axial

Protection class

I (if protective earth is connected by
customer)

Product conforming
to standard

EN 60335-1; CE

Approval

CCC

For cyclic speed loads, note that the rotating parts of the device
are designed for maximum one million load cycles. If you have
specific questions, contact ebm-papst for support.

3.5 Mounting data

For depth of screw, see chapter 3.1 Product drawing

;

Secure the mounting screws against accidentally coming loose (e.g.
by using self-locking screws).

You can obtain additional mounting data from the product drawing if
necessary.

3.6 Transport and storage conditions

;

Use the device in accordance with its protection type.

Item no. 12324-5-9970 · Revision 77012 · Release 2012-04-18 · Page 5 / 9

ebm-papst Mulfingen GmbH & Co. KG · Bachmühle 2 · D-74673 Mulfingen · Phone +49 (0) 7938 81-0 · Fax +49 (0) 7938 81-110 · [email protected] · www.ebmpapst.com

Содержание R4D310-AS18-01

Страница 1: ...em Only trained and authorised specialist personnel are permitted to transport unpack assemble operate or maintain the device or to use it in any other manner 1 3 Basic safety rules 1 1 3 Basic safety rules Any safety hazards stemming from the device must be re evaluated once it is installed in the end device Observe the following when working on the unit Do not make any modifications additions or...

Страница 2: ...ill WARNING Rotating device Long hair loose items of clothing and jewellery could become entangled and pulled into the device You could be injured Do not wear any loose clothing or jewellery while working on rotating parts Protect long hair by wearing a cap 1 7 Emission WARNING Depending on the installation and operating conditions a sound pressure level greater than 70 dB A may arise Danger of no...

Страница 3: ... the following ways is particularly prohibited and may cause hazards Operating the device with an imbalance e g caused by dirt deposits or icing Moving air that contains abrasive particles Moving highly corrosive air e g salt spray mist Exceptions are devices that are intended for salt spray mist and protected accordingly Moving air that contains dust pollution e g suctioning off saw dust Operatin...

Страница 4: ...le 31050 2 4013 not included in the standard scope of delivery other inlet nozzles on request 2 Depth of screw max 5 mm 3 Connection line AWG20 9G 0 5mm 9x brass lead tips crimped Item no 12324 5 9970 Revision 77012 Release 2012 04 18 Page 4 9 ebm papst Mulfingen GmbH Co KG Bachmühle 2 D 74673 Mulfingen Phone 49 0 7938 81 0 Fax 49 0 7938 81 110 info1 de ebmpapst com www ebmpapst com ...

Страница 5: ... of impeller Aluminium sheet Number of blades 6 Direction of rotation Clockwise seen on rotor Type of protection IP 44 Depending on installation and position as per EN 60034 5 Insulation class B Humidity class F1 2 Mounting position Any Condensate discharge holes Rotor side Operation mode S1 Motor bearing Ball bearing Touch current acc IEC 60990 measuring network Fig 4 TN system 0 75 mA Motor prot...

Страница 6: ...on follow the basic principles in accordance with EN 61800 5 1 The protective earth must have a cross section equal to or greater than the outer conductor cross section We recommend the use of 105 C cables Ensure that the minimum cable cross section is at least AWG26 0 13 mm 4 2 2 Voltage control With open loop speed control using transformers or electronic voltage regulators e g phase angle contr...

Страница 7: ... Y Star connection L1 black L2 blue L3 brown U1 black V1 blue W1 brown U2 green V2 white W2 yellow TOP 2xgrey PE green yellow Item no 12324 5 9970 Revision 77012 Release 2012 04 18 Page 7 9 ebm papst Mulfingen GmbH Co KG Bachmühle 2 D 74673 Mulfingen Phone 49 0 7938 81 0 Fax 49 0 7938 81 110 info1 de ebmpapst com www ebmpapst com ...

Страница 8: ...wer failure Danger of injury Keep out of the danger zone of the device When working on the device switch off the mains supply voltage and secure the latter from being switched on again Wait until the device stops Insert the brought out thermal overload protector into the control circuit so that the cooled off motor does not switch on independently after a fault If the device remains out of use for...

Страница 9: ...sing Visual inspection At least every 6 months Replacement of the device Mounting the connection lines Visual inspection At least every 6 months Fasten Mounting of protective earth connection Visual inspection At least every 6 months Fasten Check the insulation of the wires for damage Visual inspection At least every 6 months Replace wires Impeller for wear deposits corrosion and damage Visual ins...

Страница 10: ...Mouser Electronics Authorized Distributor Click to View Pricing Inventory Delivery Lifecycle Information ebm papst R4D310 AS18 01 ...

Отзывы: