ebm-papst R3G225-RE07-03 Скачать руководство пользователя страница 5

Operating instructions

R3G225-RE07-03

Translation of the original operating instructions

All dimensions in mm.

Inlet ring 96358-2-4013 not included in scope of delivery

Item no. 51138-5-9970 · ENU · Change 94511 · Approved 2018-06-21 · Page 5 / 12

ebm-papst Mulfingen GmbH & Co. KG · Bachmühle 2 · D-74673 Mulfingen · Phone +49 (0) 7938 81-0 · Fax +49 (0) 7938 81-110 · [email protected] · www.ebmpapst.com

Содержание R3G225-RE07-03

Страница 1: ...y authorized specialists are permitted to install the device to carry out a test run and to perform work on the electrical installation 1 3 Basic safety rules 1 1 3 Basic safety rules The safety hazar...

Страница 2: ...Electrical or electromagnetic interference after installing the device in customer equipment Verify that the entire setup is EMC compliant 1 7 Mechanical movement DANGER Rotating device Risk of injury...

Страница 3: ...ons Improper use In particular operating the device in the following ways is prohibited and could be hazardous Operating the device in an unbalanced state e g due to dirt deposits or ice formation Res...

Страница 4: ...not included in scope of delivery 2 Max clearance for screw 5 mm 3 Max clearance for screw 10 mm 4 Cable PVC 3G AWG20 3x crimped splices 5 Cable PVC 4X AWG22 4x crimped splices Item no 51138 5 9970 E...

Страница 5: ...All dimensions in mm Inlet ring 96358 2 4013 not included in scope of delivery Item no 51138 5 9970 ENU Change 94511 Approved 2018 06 21 Page 5 12 ebm papst Mulfingen GmbH Co KG Bachm hle 2 D 74673 Mu...

Страница 6: ...Pa Data obtained at optimum efficiency level The ErP data is determined using a motor impeller combination in a standardized measurement setup 3 4 Technical description Weight 1 75 kg Size 225 mm Moto...

Страница 7: ...cks Wear safety shoes and cut resistant safety gloves NOTE Damage to the device from vibration Bearing damage shorter service life The fan must not be subjected to force or excessive vibration from se...

Страница 8: ...earth conductor by way of the extra protective earth terminal provided on the device 4 2 2 Reactive currents Because of the EMC filter integrated for compliance with EMC limits interference emission a...

Страница 9: ...12 PE green yellow Ground connection 2 0 10V PWM yellow 0 10 V PWM control input Ri 100 k SELV 4 Tach white Tach output open collector 1 pulse per revolution Isink max 10 mA SELV 3 10 V red Fixed volt...

Страница 10: ...g in cyclic operation on and off via power supply Disconnect the device from the power supply When disconnecting be sure to disconnect the ground connection last 5 INTEGRATED PROTECTIVE FEATURES The...

Страница 11: ...rigorously implemented around the world on the basis of German standards Right from the development stage ecological design technical safety and health protection are fixed criteria The following sec...

Страница 12: ...mploying the proper procedures for electronic scrap Please contact ebm papst for any other questions on disposal Item no 51138 5 9970 ENU Change 94511 Approved 2018 06 21 Page 12 12 ebm papst Mulfinge...