3. TECHNICAL DATA

3.1 Product drawing

All dimensions in mm.

1

Accessory part: Inlet ring 09569-2-4013, not included in scope of delivery

2

Max. clearance for screw 6 mm

3

Max. clearance for screw 6 mm

4

Cable PVC AWG20, 3x crimped splices

5

Cable PVC 4x 0.25 mm², 4x crimped splices

Item no. 54967-5-9970 · ENU · Change 98030 · Approved 2018-04-27 · Page 4 / 12

ebm-papst Mulfingen GmbH & Co. KG · Bachmühle 2 · D-74673 Mulfingen · Phone +49 (0) 7938 81-0 · Fax +49 (0) 7938 81-110 · [email protected] · www.ebmpapst.com

Содержание R3G120-AB13-02

Страница 1: ...alified trained and authorized technical staff Only authorized specialists are permitted to install the device to carry out a test run and to perform work on the electrical installation 1 3 Basic safe...

Страница 2: ...Electrical or electromagnetic interference after installing the device in customer equipment Verify that the entire setup is EMC compliant 1 7 Mechanical movement DANGER Rotating device Risk of injury...

Страница 3: ...ons Improper use In particular operating the device in the following ways is prohibited and could be hazardous Operating the device in an unbalanced state e g due to dirt deposits or ice formation Res...

Страница 4: ...3 not included in scope of delivery 2 Max clearance for screw 6 mm 3 Max clearance for screw 6 mm 4 Cable PVC AWG20 3x crimped splices 5 Cable PVC 4x 0 25 mm 4x crimped splices Item no 54967 5 9970 EN...

Страница 5: ...nsions in mm 1 Accessory part inlet ring 09569 2 4013 not included in scope of delivery Item no 54967 5 9970 ENU Change 98030 Approved 2018 04 27 Page 5 12 ebm papst Mulfingen GmbH Co KG Bachm hle 2 D...

Страница 6: ...standards EN 60335 1 Approval CSA C22 2 No 77 CAN CSA E60730 1 EAC UL 1004 3 60730 1 With regard to cyclic speed loads note that the rotating parts of the device are designed for a maximum of one mil...

Страница 7: ...can damage the device Make sure the end of the cable is connected in a dry environment Only connect the device to circuits that can be switched off with an all pole disconnection switch 4 2 1 Require...

Страница 8: ...current FLA 4 3 Plug connection 4 3 1 Making supply connections Check your connector s pin assignment Connect the built in connector with the mating connector Ensure that the connector is properly en...

Страница 9: ...utral conductor 4 GND blue GND connection for control interface 5 Tach white Tach output open collector 1 pulse per revolution electrically isolated 6 10V max 1 1mA red Voltage output 10 V 1 1mA elect...

Страница 10: ...via power supply Disconnect the device from the power supply When disconnecting be sure to disconnect the ground connection last 5 INTEGRATED PROTECTIVE FEATURES The integrated protective functions c...

Страница 11: ...noise acoustic At least every 6 months Replace device 6 3 Disposal For ebm papst environmental protection and resource preservation are top priority corporate goals ebm papst operates an environmenta...

Страница 12: ...s Miscellaneous insulators used in the terminal box Power cables Cables for internal wiring Electrolytic capacitors Dispose of electronic components employing the proper procedures for electronic scra...

Отзывы: