background image

Operating instructions

R2E250-AT02-11

Translation of the original operating instructions

3.2 Nominal data

Motor

M2E074-EI

Phase

1~

1~

1~

Nominal voltage / VAC

115

115

115

Frequency / Hz

50

60

60

Type of data definition

fa

fa

fa

Valid for approval /
standard

CE

CE

UL

Speed / min

-1

2800

3250

3250

Power input / W

210

355

370

Current draw / A

1.85

3.1

Motor capacitor / µF

20

20

20

Capacitor voltage / VDB

250

250

250

Capacitor standard

P2 (CE)

P2 (CE)

Min. back pressure / Pa

0

0

0

Max. ambient
temperature / °C

-

50

50

Starting current / A

6.2

5.5

5.5

ml = max. load · me = max. efficiency · fa = running at free air

cs = customer specs · cu = customer unit

Subject to alterations

3.3 Technical features

Mass

4.1 kg

Size

250 mm

Surface of rotor

Coated in black

Material of impeller

Plastic PA6, fibreglass-reinforced

Number of blades

11

Direction of rotation

Clockwise, seen on rotor

Type of protection

IP 44

Insulation class

"F"

Humidity class

F5

Mounting position

Any

Condensate discharge
holes

Rotor-side

Operation mode

S1

Motor bearing

Ball bearing

Touch current acc.
IEC 60990 (measuring
network Fig. 4, TN
system)

< 0.75 mA

Motor protection

Thermal overload protector (TOP) wired
internally

Cable exit

Variable

Protection class

I (if protective earth is connected by
customer)

Product conforming
to standard

EN 60335-1; CE

Approval

UL 1004-1; CSA C22.2 Nr.100

For cyclic speed loads, note that the rotating parts of the device
are designed for maximum one million load cycles. If you have
specific questions, contact ebm-papst for support.

3.4 Mounting data

For depth of screw, see chapter 3.1 Product drawing

;

Secure the mounting screws against accidentally coming loose (e.g.
by using self-locking screws).

Strength class for
mounting screws

8.8

You can obtain additional mounting data from the product drawing if
necessary.

3.5 Transport and storage conditions

;

Use the device in accordance with its protection type.

Max. permissible
ambient motor temp.
(transp./ storage)

+ 80 °C

Min. permissible
ambient motor temp.
(transp./storage)

- 40 °C

Item no. 10503-5-9970 · Revision - · Release 2011-12-08 · Page 5 / 9

ebm-papst Mulfingen GmbH & Co. KG · Bachmühle 2 · D-74673 Mulfingen · Phone +49 (0) 7938 81-0 · Fax +49 (0) 7938 81-110 · [email protected] · www.ebmpapst.com

Содержание R2E250-AT02-11

Страница 1: ...system Only trained and authorised specialist personnel are permitted to transport unpack assemble operate or maintain the device or to use it in any other manner 1 3 Basic safety rules 1 1 3 Basic s...

Страница 2: ...eller can be injured Secure the device against accidental contact Before working on the system machine wait until all parts have come to a standstill WARNING Rotating device Long hair loose items of c...

Страница 3: ...per use Using the device in the following ways is particularly prohibited and may cause hazards Operating the device with an imbalance e g caused by dirt deposits or icing Moving air that contains abr...

Страница 4: ...nection line PFA 4x brass lead tips crimped 2 Accessory part Inlet nozzle 96359 2 4013 not included in the standard scope of delivery 3 Depth of screw max 10 mm Item no 10503 5 9970 Revision Release 2...

Страница 5: ...earing Ball bearing Touch current acc IEC 60990 measuring network Fig 4 TN system 0 75 mA Motor protection Thermal overload protector TOP wired internally Cable exit Variable Protection class I if pro...

Страница 6: ...witched on again NOTE Water penetration into leads or wires Water enters at the cable end on the customers side and can damage the device Make sure that the cable end is connected in a dry environment...

Страница 7: ...instructions 4 4 Connection screen U1 blue Z brown U2 black PE green yellow Item no 10503 5 9970 Revision Release 2011 12 08 Page 7 9 ebm papst Mulfingen GmbH Co KG Bachm hle 2 D 74673 Mulfingen Phone...

Страница 8: ...ed off Electric shock risk of injury Discharge the capacitors before working on the device CAUTION The motor restarts automatically when operating voltage is applied e g after a power failure Danger o...

Страница 9: ...or damage to blades and housing Visual inspection At least every 6 months Replacement of the device Mounting the connection lines Visual inspection At least every 6 months Fasten Mounting of protectiv...

Отзывы: