background image

Operating instructions

R2E190-RB88-14

Translation of the original operating instructions

3.2 Nominal data

Motor

M2E068-CF

Phase

2~

2~

Nominal voltage / VAC

400

400

Frequency / Hz

50

60

Method of obtaining
data

ml

ml

Valid for approval/
standard

CE

CE

Speed (rpm) / min

-1

2730

3150

Power consumption / W

80

100

Current draw / A

0.22

0.27

Capacitor / µF

1

1

Capacitor voltage / VDB

700

700

Capacitor standard

S0 (CE)

S0 (CE)

Min. back pressure / Pa

0

0

Min. ambient
temperature / °C

-25

-25

Max. ambient
temperature / °C

30

55

Starting current / A

0.47

0.48

ml = Max. load · me = Max. efficiency · fa = Free air

cs = Customer specification · ce = Customer equipment

Subject to change

3.3 Technical description

Weight

1.7 kg

Size

190 mm

Motor size

68

Rotor surface

Unpainted

Impeller material

PP plastic

Number of blades

7

Direction of rotation

Clockwise, viewed toward rotor

Degree of protection

IP44; installation- and position-dependent

Insulation class

"B"

Moisture (F) /
Environmental (H)
protection class

H0 - dry environment

Installation position

Any

Condensation
drainage holes

None

Mode

S1

Motor bearing

Ball bearing

Touch current
according to IEC
60990 (measuring
circuit Fig. 4, TN
system)

< 0.75 mA

Motor protection

Thermal overload protector (TOP)
internally connected

with cable

Variable

Pollution degree

2

Protection class
assignment

I; If a protective earth is connected by
the customer
This component for installation may
have several local protection classes.
This information relates to this
component’s basic design.
The final protection class is based on
the component’s intended installation and
connection.

Conformity with
standards

EN 60034-1; EN 60204-1; EN 60335-1;
CE

;

Use the device in accordance with its degree of protection.

Information on surface quality

The surfaces of the products conform to the generally applicable industrial
standard. The surface quality may change during the production period.
This has no effect on strength, dimensional stability and dimensional
accuracy.
The color pigments in the paints used perceptibly react to UV light over
the course of time. The product is to be protected against UV radiation to
prevent the formation of patches and fading. Changes in color are not a
reason for complaint and are not covered by the warranty. UV radiation
in the frequency range and the intensity of natural solar radiation has no
effect on the technical properties of the products.

3.4 Mounting data

Any further mounting data required can be taken from the product
drawing or Section Chapter 4.1 Mechanical connection.

Strength class of
screws

8.8

For screw clearance, see Chapter 3.1 Product drawing

;

Secure the screws against unintentional loosening (e.g. use self-
locking screws).

3.5 Transport and storage conditions

Max. permitted
ambient temp. for
motor (transport/
storage)

+80 °C

Min. permitted
ambient temp. for
motor (transport/
storage)

-40 °C

Item no. 14086-5-9970 · ENU · Change 200889 · Approved 2021-11-30 · Page 6 / 12

ebm-papst Mulfingen GmbH & Co. KG · Bachmühle 2 · D-74673 Mulfingen · Phone +49 (0) 7938 81-0 · Fax +49 (0) 7938 81-110 · [email protected] · www.ebmpapst.com

Содержание R2E190-RB88-14

Страница 1: ...d otherwise used by suitably qualified trained and authorized technical staff Only authorized specialists are permitted to install the device to carry out a test run and to perform work on the electri...

Страница 2: ...efore working on the system machine wait until all parts have come to a standstill WARNING Rotating device Long hair and dangling items of clothing jewelry and the like can become entangled and be pul...

Страница 3: ...ing the device in an unbalanced state e g due to dirt deposits or ice formation Resonant operation operation with severe vibration This also includes vibration transmitted to the fan from the customer...

Страница 4: ...Accessory part Inlet ring 09576 2 4013 not included in scope of delivery 2 Max clearance for screw 5 mm 3 Cable PVC 4G 0 5 mm 4x splice Item no 14086 5 9970 ENU Change 200889 Approved 2021 11 30 Page...

Страница 5: ...sions in mm 1 Accessory part inlet ring 09576 2 4013 not included in scope of delivery Item no 14086 5 9970 ENU Change 200889 Approved 2021 11 30 Page 5 12 ebm papst Mulfingen GmbH Co KG Bachm hle 2 D...

Страница 6: ...s information relates to this component s basic design The final protection class is based on the component s intended installation and connection Conformity with standards EN 60034 1 EN 60204 1 EN 60...

Страница 7: ...formation on the nameplate matches the connection data If the motor run capacitor was not installed by ebm papst check whether the information on the motor run capacitor matches the information on the...

Страница 8: ...st connect the PE protective earth Connect the cables according to your application When doing so observe Chapter 4 4 Connection diagram Item no 14086 5 9970 ENU Change 200889 Approved 2021 11 30 Page...

Страница 9: ...ctions 4 4 Connection diagram U1 blue Z brown U2 black PE Green yellow Item no 14086 5 9970 ENU Change 200889 Approved 2021 11 30 Page 9 12 ebm papst Mulfingen GmbH Co KG Bachm hle 2 D 74673 Mulfingen...

Страница 10: ...AINTENANCE MALFUNCTIONS POSSIBLE CAUSES AND REMEDIES Do not perform any repairs on your device Send the device to ebm papst for repair or replacement WARNING Live terminals and connections even with d...

Страница 11: ...least every 6 months Fasten Fastening the protective earth terminal Visual inspection At least every 6 months Fasten Insulation of cables for damage Visual inspection At least every 6 months Replace c...

Страница 12: ...aterials and are therefore to be treated in the same manner The materials concerned are as follows Miscellaneous insulators used in the terminal box Power cables Cables for internal wiring Electrolyti...