3. TECHNICAL DATA

3.1 Product drawing

All measures have the unit mm.

1

Connection line PVC 3X AWG18, 3x brass lead tips crimped

2

Connection line Raychem 3X AWG24 for Hall IC, 3 x brass lead tips crimped

3

Accessory part: Inlet nozzle 09576-2-4013, not included in the standard scope of delivery

4

Depth of screw max. 5 mm

Item no. 11352-5-9970 · Revision 73098 · Release 2011-01-21 · Page 4 / 9

ebm-papst Mulfingen GmbH & Co. KG · Bachmühle 2 · D-74673 Mulfingen · Phone +49 (0) 7938 81-0 · Fax +49 (0) 7938 81-110 · [email protected] · www.ebmpapst.com

Содержание R2E190-AO50-96

Страница 1: ...stem Only trained and authorised specialist personnel are permitted to transport unpack assemble operate or maintain the device or to use it in any other manner 1 3 Basic safety rules 1 1 3 Basic safe...

Страница 2: ...could become entangled and pulled into the device You could be injured Do not wear any loose clothing or jewellery while working on rotating parts Protect long hair by wearing a cap 1 7 Emission WARNI...

Страница 3: ...use Using the device in the following ways is particularly prohibited and may cause hazards Operating the device with an imbalance e g caused by dirt deposits or icing Moving air that contains abrasi...

Страница 4: ...crimped 2 Connection line Raychem 3X AWG24 for Hall IC 3 x brass lead tips crimped 3 Accessory part Inlet nozzle 09576 2 4013 not included in the standard scope of delivery 4 Depth of screw max 5 mm...

Страница 5: ...1 Motor bearing Ball bearing Touch current acc IEC 60990 measuring network Fig 4 TN system 0 75 mA Motor protection Thermal overload protector TOP wired internally Cable exit Variable Protection class...

Страница 6: ...be switched off using an all pole disconnecting switch 4 2 1 Prerequisites Check whether the data on the type plate agree with the connection data and the data of the operating capacitor Before conne...

Страница 7: ...connection diagram U1 Blue Z brown U2 black 2 Hall IC circuit 2 1 Hall IC 2 2 Red 5V 2 3 White out 2 4 Black 0V Item no 11352 5 9970 Revision 73098 Release 2011 01 21 Page 7 9 ebm papst Mulfingen GmbH...

Страница 8: ...off Electric shock risk of injury Discharge the capacitors before working on the device CAUTION The motor restarts automatically when operating voltage is applied e g after a power failure Danger of i...

Страница 9: ...placement of the device Check the device for damage to blades and housing Visual inspection At least every 6 months Replacement of the device Mounting the connection lines Visual inspection At least e...

Отзывы: