background image

Operating instructions

R2E180-CV82-05

Translation of the original operating instructions

3. TECHNICAL DATA

3.1 Product drawing

All dimensions in mm.

1

3-pole connector housing Wieland 93.032.3357.0

1.1

L (blue)

1.2

PE (green/yellow)

1.3

N (black + capacitor)

2

3-pole connector housing Wieland 93.031.3257.0

2.1

GND (black)

2.2

out (white)

2.3

VCC (red)

Item no. 14400-5-9970 · ENU · Change 202174 · Approved 2019-01-03 · Page 4 / 10

ebm-papst Mulfingen GmbH & Co. KG · Bachmühle 2 · D-74673 Mulfingen · Phone +49 (0) 7938 81-0 · Fax +49 (0) 7938 81-110 · [email protected] · www.ebmpapst.com

Содержание R2E180-CV82-05

Страница 1: ...used by suitably qualified trained and authorized technical staff Only authorized specialists are permitted to install the device to carry out a test run and to perform work on the electrical install...

Страница 2: ...coming into contact with the rotor or the impeller Secure the device against accidental contact Before working on the system machine wait until all parts have come to a standstill WARNING Rotating dev...

Страница 3: ...ing the device in an unbalanced state e g due to dirt deposits or ice formation Resonant operation operation with severe vibration This also includes vibration transmitted to the fan from the customer...

Страница 4: ...Wieland 93 032 3357 0 1 1 L blue 1 2 PE green yellow 1 3 N black capacitor 2 3 pole connector housing Wieland 93 031 3257 0 2 1 GND black 2 2 out white 2 3 VCC red Item no 14400 5 9970 ENU Change 2021...

Страница 5: ...ve earth Motor capacitor according to EN 60252 1 in safety protection class S0 Conformity with standards EN 60335 1 CE With regard to cyclic speed loads note that the rotating parts of the device are...

Страница 6: ...able is connected in a dry environment Only connect the device to circuits that can be switched off with an all pole disconnection switch 4 2 1 Requirements Check whether the information on the namepl...

Страница 7: ...onnector Ensure that the connector is properly engaged 4 4 Connection of the Hall IC The device has external leads Connect the cables according to your application When doing so observe Chapter 4 5 Co...

Страница 8: ...tion diagram L blue N black PE green yellow 2 Hall IC circuit 2 1 Hall IC 2 2 red VCC 2 3 white out 2 4 black GND Item no 14400 5 9970 ENU Change 202174 Approved 2019 01 03 Page 8 10 ebm papst Mulfing...

Страница 9: ...your device Send the device to ebm papst for repair or replacement WARNING Live terminals and connections even with device switched off Electric shock Wait five minutes after disconnecting the voltag...

Страница 10: ...icable country specific legal regulations with regard to the disposal of products or waste occurring in the various phases of the life cycle The corresponding disposal standards are also to be heeded...

Отзывы: