background image

Operating instructions

R2E180-AH05-10

Translation of the original operating instructions

4.4 Connection diagram

Single-phase AC motor with motor run capacitor

1

Clockwise operation

2

Counterclockwise operation

U1

black

U2

gray

Z1

blue

Z2

brown

Item no. 14645-5-9970 · ENU · Change 89188 · Approved 2016-08-25 · Page 8 / 10

ebm-papst Mulfingen GmbH & Co. KG · Bachmühle 2 · D-74673 Mulfingen · Phone +49 (0) 7938 81-0 · Fax +49 (0) 7938 81-110 · [email protected] · www.ebmpapst.com

Содержание R2E180-AH05-10

Страница 1: ...otherwise used by suitably qualified trained and authorized technical staff Only authorized specialists are permitted to install the device to carry out a test run and to perform work on the electrica...

Страница 2: ...coming into contact with the rotor or the impeller Secure the device against accidental contact Before working on the system machine wait until all parts have come to a standstill WARNING Rotating de...

Страница 3: ...ticular operating the device in the following ways is prohibited and could be hazardous Operating the device in an unbalanced state e g due to dirt deposits or ice formation Resonant operation operati...

Страница 4: ...vanized 2 Centrifugal fan impeller sheet steel rust and acid resistant 3 1 black 3 2 brown 3 3 blue 3 4 gray 4 M4 screw for fastening ground connector Max clearance for screw 5 mm Item no 14645 5 9970...

Страница 5: ...1 CE With regard to cyclic speed loads note that the rotating parts of the device are designed for a maximum of one million load cycles If you have special questions consult ebm papst for support Use...

Страница 6: ...connection switch 4 2 1 Requirements Check whether the information on the nameplate matches the connection data If the motor run capacitor was not installed by ebm papst check whether the information...

Страница 7: ...d by moisture penetration Moisture can penetrate into the terminal box if water is constantly present at the cable glands To prevent the constant accumulation of water at the cable glands the cable sh...

Страница 8: ...motor with motor run capacitor 1 Clockwise operation 2 Counterclockwise operation U1 black U2 gray Z1 blue Z2 brown Item no 14645 5 9970 ENU Change 89188 Approved 2016 08 25 Page 8 10 ebm papst Mulfi...

Страница 9: ...MAINTENANCE MALFUNCTIONS POSSIBLE CAUSES AND REMEDIES Do not perform any repairs on your device Send the device to ebm papst for repair or replacement WARNING Live terminals and connections even with...

Страница 10: ...e various phases of the life cycle The corresponding disposal standards are also to be heeded 5 3 2 Disassembly Disassembly of the product must be performed or supervised by qualified personnel with t...