ebm-papst R2D250-AF10-12 Скачать руководство пользователя страница 5

Operating instructions

R2D250-AF10-12

Translation of the original operating instructions

3.2 Nominal data

Motor

M2D068-EC

Phase

3~

Nominal voltage / VAC

400

Connection

Y

Frequency / Hz

50

Type of data definition

fa

Valid for approval /
standard

CE

Speed / min

-1

2600

Power input / W

160

Current draw / A

0.26

Min. back pressure / Pa

0

Max. ambient
temperature / °C

70

Starting current / A

0.93

ml = max. load · me = max. efficiency · fa = running at free air

cs = customer specs · cu = customer unit

Subject to alterations

3.3 Technical features

Mass

3.1 kg

Size

250 mm

Surface of rotor

Coated in black

Material of impeller

Plastic PA66, fibreglass-reinforced

Number of blades

11

Direction of rotation

Clockwise, seen on rotor

Type of protection

IP 44; Depending on installation and
position

Insulation class

"F"

Humidity class

F5

Mounting position

Any

Condensate discharge
holes

None

Operation mode

S1

Motor bearing

Ball bearing

Touch current acc.
IEC 60990 (measuring
network Fig. 4, TN
system)

< 0.75 mA

Motor protection

Thermal overload protector (TOP)
brought out

Cable exit

Lateral

Protection class

I (if protective earth is connected by
customer)

Product conforming
to standard

EN 60335-1; CE

For cyclic speed loads, note that the rotating parts of the device
are designed for maximum one million load cycles. If you have
specific questions, contact ebm-papst for support.

3.4 Mounting data

For depth of screw, see chapter 3.1 Product drawing

;

Secure the mounting screws against accidentally coming loose (e.g.
by using self-locking screws).

Strength class for
mounting screws

8.8

You can obtain additional mounting data from the product drawing if
necessary.

3.5 Transport and storage conditions

;

Use the device in accordance with its protection type.

Max. permissible
ambient motor temp.
(transp./ storage)

+ 80 °C

Min. permissible
ambient motor temp.
(transp./storage)

- 40 °C

Item no. 11646-5-9970 · Revision - · Release 2011-07-14 · Page 5 / 9

ebm-papst Mulfingen GmbH & Co. KG · Bachmühle 2 · D-74673 Mulfingen · Phone +49 (0) 7938 81-0 · Fax +49 (0) 7938 81-110 · [email protected] · www.ebmpapst.com

Содержание R2D250-AF10-12

Страница 1: ...n the electrical system Only trained and authorised specialist personnel are permitted to transport unpack assemble operate or maintain the device or to use it in any other manner 1 3 Basic safety rul...

Страница 2: ...still WARNING Rotating device Long hair loose items of clothing and jewellery could become entangled and pulled into the device You could be injured Do not wear any loose clothing or jewellery while w...

Страница 3: ...in the following ways is particularly prohibited and may cause hazards Operating the device with an imbalance e g caused by dirt deposits or icing Moving air that contains abrasive particles Moving hi...

Страница 4: ...line silicone 6G 0 5 mm 6 x brass lead tips crimped 2 Accessory part Inlet nozzle 96359 2 4013 not included in the standard scope of delivery 3 Depth of screw max 5 mm Item no 11646 5 9970 Revision R...

Страница 5: ...cc IEC 60990 measuring network Fig 4 TN system 0 75 mA Motor protection Thermal overload protector TOP brought out Cable exit Lateral Protection class I if protective earth is connected by customer Pr...

Страница 6: ...tion follow the basic principles in accordance with EN 61800 5 1 The protective earth must have a cross section equal to or greater than the outer conductor cross section We recommend the use of 105 C...

Страница 7: ...nection screen L1 U1 black L2 V1 blue L3 W1 brown PE green yellow TOP 2 x grey Y Star connection Item no 11646 5 9970 Revision Release 2011 07 14 Page 7 9 ebm papst Mulfingen GmbH Co KG Bachm hle 2 D...

Страница 8: ...power failure Danger of injury Keep out of the danger zone of the device When working on the device switch off the mains supply voltage and secure the latter from being switched on again Wait until th...

Страница 9: ...the device Check the device for damage to blades and housing Visual inspection At least every 6 months Replacement of the device Mounting the connection lines Visual inspection At least every 6 month...

Отзывы: