3. TECHNICAL DATA

3.1 Product drawing

All dimensions in mm.

1

Accessory part: Inlet ring 09609-2-4013, not included in scope of delivery

2

Max. clearance for screw 5 mm

3

Cable PVC 4G 0.5 mm², 4-pole connector housing tyco 350779-5, 4x socket tyco 926882-1

3.1

L1

3.2

L2

3.3

L3

3.4

PE

Item no. 10784-5-9970 · ENU · Change 85820 · Approved 2017-01-12 · Page 4 / 10

ebm-papst Mulfingen GmbH & Co. KG · Bachmühle 2 · D-74673 Mulfingen · Phone +49 (0) 7938 81-0 · Fax +49 (0) 7938 81-110 · [email protected] · www.ebmpapst.com

Содержание R2D220-AC02-12

Страница 1: ...ned and otherwise used by suitably qualified trained and authorized technical staff Only authorized specialists are permitted to install the device to carry out a test run and to perform work on the e...

Страница 2: ...st accidental contact Before working on the system machine wait until all parts have come to a standstill WARNING Rotating device Long hair and dangling items of clothing jewelry and the like can beco...

Страница 3: ...perating instructions Improper use In particular operating the device in the following ways is prohibited and could be hazardous Operating the device in an unbalanced state e g due to dirt deposits or...

Страница 4: ...not included in scope of delivery 2 Max clearance for screw 5 mm 3 Cable PVC 4G 0 5 mm 4 pole connector housing tyco 350779 5 4x socket tyco 926882 1 3 1 L1 3 2 L2 3 3 L3 3 4 PE Item no 10784 5 9970 E...

Страница 5: ...te that the rotating parts of the device are designed for a maximum of one million load cycles If you have special questions consult ebm papst for support Use the device in accordance with its degree...

Страница 6: ...nnection switch 4 2 1 Requirements Check whether the information on the nameplate matches the connection data Before connecting the device make sure the power supply matches the device voltage Only us...

Страница 7: ...any automatic overheating protection The device can become hot and catch fire For the version without thermal overload protector also install a suitable motor protection switch Item no 10784 5 9970 E...

Страница 8: ...tion direction by reversing two phases Three phase motor Y Star connection L1 black L2 blue L3 brown PE green yellow Item no 10784 5 9970 ENU Change 85820 Approved 2017 01 12 Page 8 10 ebm papst Mulfi...

Страница 9: ...o disconnect the ground connection last 5 MAINTENANCE MALFUNCTIONS POSSIBLE CAUSES AND REMEDIES Do not perform any repairs on your device Send the device to ebm papst for repair or replacement WARNING...

Страница 10: ...o to be heeded 5 3 2 Disassembly Disassembly of the product must be performed or supervised by qualified personnel with the appropriate technical knowledge The product is to be disassembled into suita...

Отзывы: