3. TECHNICAL DATA

3.1 Product drawing

All dimensions in mm.

1

Centrifugal fan impeller (sheet steel, galvanized)

2

Centrifugal fan impeller (sheet steel, rust and acid-resistant)

3.1

brown

3.2

blue

3.3

black

3.4

white

3.5

green

3.6

yellow

4

M4 screw for fastening ground connector
Max. clearance for screw 5 mm

Item no. 14644-5-9970 · ENU · Change 99359 · Approved 2018-04-26 · Page 4 / 10

ebm-papst Mulfingen GmbH & Co. KG · Bachmühle 2 · D-74673 Mulfingen · Phone +49 (0) 7938 81-0 · Fax +49 (0) 7938 81-110 · [email protected] · www.ebmpapst.com

Содержание R2D180-AH06-06

Страница 1: ...otherwise used by suitably qualified trained and authorized technical staff Only authorized specialists are permitted to install the device to carry out a test run and to perform work on the electric...

Страница 2: ...st accidental contact Before working on the system machine wait until all parts have come to a standstill WARNING Rotating device Long hair and dangling items of clothing jewelry and the like can beco...

Страница 3: ...perating instructions Improper use In particular operating the device in the following ways is prohibited and could be hazardous Operating the device in an unbalanced state e g due to dirt deposits or...

Страница 4: ...entrifugal fan impeller sheet steel rust and acid resistant 3 1 brown 3 2 blue 3 3 black 3 4 white 3 5 green 3 6 yellow 4 M4 screw for fastening ground connector Max clearance for screw 5 mm Item no 1...

Страница 5: ...e rotating parts of the device are designed for a maximum of one million load cycles If you have special questions consult ebm papst for support Use the device in accordance with its degree of protect...

Страница 6: ...tion on the nameplate matches the connection data Before connecting the device make sure the power supply matches the device voltage Only use cables designed for the current level indicated on the nam...

Страница 7: ...any automatic overheating protection The device can become hot and catch fire For the version without thermal overload protector also install a suitable motor protection switch Item no 14644 5 9970 E...

Страница 8: ...eversing two phases Three phase motor Delta connection Y Star connection L1 U1 black L2 V1 blue L3 W1 brown U2 green V2 white W2 yellow Item no 14644 5 9970 ENU Change 99359 Approved 2018 04 26 Page 8...

Страница 9: ...NCTIONS POSSIBLE CAUSES AND REMEDIES Do not perform any repairs on your device Send the device to ebm papst for repair or replacement WARNING Live terminals and connections even with device switched o...

Страница 10: ...r supervised by qualified personnel with the appropriate technical knowledge The product is to be disassembled into suitable components for disposal employing standard procedures for motors WARNING He...