Operating instructions
R1G250-AQ37-52
Translation of the original operating instructions
4.4 Connection diagram
Drawing preliminary!
No.
Conn.
Designation
Color
Function/assignment
1
1
Un +48 VDC
red
Power supply 48 VDC, maximum ripple 3.5%
1
2
PWM / lin
yellow
PWM / lin. Control input 0-10 V
1
3
Tach
white
Tach output, 3 pulses per revolution, Isink max = 10 mA
1
4
GND
blue
Reference ground
Item no. 51219-5-9970 · ENU · Change 204653 · Approved 2020-01-07 · Page 7 / 10