background image

Operating instructions

M4Q045-CA27-04

Translation of the original operating instructions

3. TECHNICAL DATA

3.1 Product drawing

All dimensions in mm.

1

Cable PVC 3x 0.5 mm², 3x crimped splices

2

Tightening torque for nuts to fasten fan housing or fan guard: 2.3 Nm

3

Tightening torque for screw to fasten fan impeller: 1.4 Nm

4

Tightening torque for nuts to fasten mounting bracket: 2.3 Nm

5

Direction of rotation counterclockwise, viewed toward shaft end

Item no. 11202-5-9970 · ENU · Change 204653 · Approved 2020-09-08 · Page 4 / 9

ebm-papst Mulfingen GmbH & Co. KG · Bachmühle 2 · D-74673 Mulfingen · Phone +49 (0) 7938 81-0 · Fax +49 (0) 7938 81-110 · [email protected] · www.ebmpapst.com

Содержание M4Q045-CA27-04

Страница 1: ...d maintained and otherwise used by suitably qualified trained and authorized technical staff Only authorized specialists are permitted to install the device to carry out a test run and to perform work...

Страница 2: ...ny loose fitting or dangling clothing or jewelry while working on rotating parts Protect long hair with a cap WARNING Ejected parts If the motor is operated with attached fan blades missing protective...

Страница 3: ...with severe vibration oscillation This also includes vibration transmitted to the motor from the customer installation Operation in medical equipment with a life sustaining or life support function Co...

Страница 4: ...an housing or fan guard 2 3 Nm 3 Tightening torque for screw to fasten fan impeller 1 4 Nm 4 Tightening torque for nuts to fasten mounting bracket 2 3 Nm 5 Direction of rotation counterclockwise viewe...

Страница 5: ...arts of the device are designed for a maximum of one million load cycles If you have special questions consult ebm papst for support Use the device in accordance with its degree of protection Informat...

Страница 6: ...for the current level indicated on the nameplate For determining the cross section note the sizing criteria according to EN 61800 5 1 The protective earth must have a cross section equal to or greater...

Страница 7: ...instructions 4 4 Connection diagram L blue PE green yellow N brown Item no 11202 5 9970 ENU Change 204653 Approved 2020 09 08 Page 7 9 ebm papst Mulfingen GmbH Co KG Bachm hle 2 D 74673 Mulfingen Phon...

Страница 8: ...ff isolate from supply and remove mechanical blockage Line voltage faulty Check line voltage restore power supply Faulty connection Isolate from supply correct connection see connection diagram Imperm...

Страница 9: ...inum Non ferrous metal e g motor windings Plastics particularly with brominated flame retardants in accordance with marking Insulating materials Cables and wires Electronic scrap e g circuit boards On...

Отзывы: