ebm-papst M4E068-CF01-01 Скачать руководство пользователя страница 5

Operating instructions

M4E068-CF01-01

Translation of the original operating instructions

3.2 Nominal data

Motor

M4E068-CF

Phase

1~

Nominal voltage / VAC

230

Frequency / Hz

50

Method of obtaining
data

me

Valid for approval/
standard

CE

Speed (rpm) / min

-1

1250

Power consumption / W

62

Power output / W

31

Current draw / A

0.28

Rated torque / Ncm

24

Mean starting torque
/ Ncm

13

Capacitor / µF

1.5

Capacitor voltage / VDB

450

Min. ambient
temperature / °C

-25

Max. ambient
temperature / °C

45

Starting current / A

0.44

ml = Max. load · me = Max. efficiency · fa = Free air

cs = Customer specification · ce = Customer equipment

Subject to change

3.3 Technical description

Weight

1.4 kg

Motor size

68

Rotor surface

Painted black

Direction of rotation

Right and left

Degree of protection

IP00

Insulation class

"B"

Moisture (F) /
Environmental (H)
protection class

H0 - dry environment

Installation position

Any

Condensation
drainage holes

None, open rotor

Mode

S1

Motor bearing

Ball bearing

Touch current
according to IEC
60990 (measuring
circuit Fig. 4, TN
system)

< 0.75 mA

Pollution degree

2

Protection class

I (with customer connection of protective
earth)

Conformity with
standards

EN 60335-1

With regard to cyclic speed loads, note that the rotating parts of
the device are designed for a maximum of one million load
cycles. If you have special questions, consult ebm-papst for
support.

;

Use the device in accordance with its degree of protection.

Information on surface quality

The surfaces of the products conform to the generally applicable industrial
standard. The surface quality may change during the production period.
This has no effect on strength, dimensional stability and dimensional
accuracy.
The color pigments in the paints used perceptibly react to UV light over
the course of time. This does not however in any way affect the
technical properties of the products. The product is to be protected against
UV radiation to prevent the formation of patches and fading. Changes in
color are not a reason for complaint and are not covered by the warranty.

3.4 Mounting data

For screw clearance, see Chapter 3.1 Product drawing

;

Secure the screws against unintentional loosening (e.g. use self-
locking screws).

Strength class of
screws

8.8

Any further mounting data required can be taken from the product
drawing or Section Chapter 4.1 Mechanical connection.

3.5 Transport and storage conditions

Max. permitted
ambient temp. for
motor (transport/
storage)

+ 80 °C

Min. permitted
ambient temp. for
motor (transport/
storage)

- 40 °C

Item no. 12323-5-9970 · ENU · Change 202174 · Approved 2018-12-28 · Page 5 / 10

ebm-papst Mulfingen GmbH & Co. KG · Bachmühle 2 · D-74673 Mulfingen · Phone +49 (0) 7938 81-0 · Fax +49 (0) 7938 81-110 · [email protected] · www.ebmpapst.com

Содержание M4E068-CF01-01

Страница 1: ...stalled operated maintained and otherwise used by suitably qualified trained and authorized technical staff Only authorized specialists are permitted to install the device to carry out a test run and...

Страница 2: ...om vibration in the original packaging in a clean environment Protect the device against environmental effects and dirt until final installation We recommend storing the device for no longer than one...

Страница 3: ...ns Operation with completely or partially disassembled or manipulated protective devices In addition all applications not listed among the intended uses Item no 12323 5 9970 ENU Change 202174 Approved...

Страница 4: ...ct drawing All dimensions in mm 1 Max clearance for screw 5 mm 2 Cable PVC 4X 0 5 mm 4x crimped splices Item no 12323 5 9970 ENU Change 202174 Approved 2018 12 28 Page 4 10 ebm papst Mulfingen GmbH Co...

Страница 5: ...mum of one million load cycles If you have special questions consult ebm papst for support Use the device in accordance with its degree of protection Information on surface quality The surfaces of the...

Страница 6: ...or the current level indicated on the nameplate For determining the cross section note the sizing criteria according to EN 61800 5 1 The protective earth must have a cross section equal to or greater...

Страница 7: ...any automatic overheating protection The device can become hot and catch fire For the version without thermal overload protector also install a suitable motor protection switch Item no 12323 5 9970 EN...

Страница 8: ...motor with motor run capacitor 1 Clockwise operation 2 Counterclockwise operation U1 black U2 gray Z1 blue Z2 brown Item no 12323 5 9970 ENU Change 202174 Approved 2018 12 28 Page 8 10 ebm papst Mulf...

Страница 9: ...t is to be started up and operated at full speed for at least two hours once a month to move the bearings and allow any condensate that may have ingressed to evaporate Malfunction fault Possible cause...

Страница 10: ...tallic materials are generally considered to be fully recyclable Separate the components for recycling into the following categories Steel and iron Aluminum Non ferrous metal e g motor windings Plasti...

Страница 11: ...Mouser Electronics Authorized Distributor Click to View Pricing Inventory Delivery Lifecycle Information ebm papst M4E068 CF01 01...

Отзывы: