background image

Operating instructions

M3G084-DF18-81

Translation of the original operating instructions

3. TECHNICAL DATA

3.1 Product drawing

All dimensions in mm.

1

Direction of rotation counterclockwise, viewed toward shaft

2

Through-hole for M8 screw

3

Max. clearance for screw 10 mm

4

Max. clearance for screw 12 mm

5

Cable PVC AWG22
3x wire-end ferrule

6

Cable PVC AWG18
5x wire-end ferrule

7

Groove depth 3 mm

8

Key DIN 6885 - A - 5 x 5 x 22

Fa

Max. permissible axial load: 150 N

Fr

Max. permissible radial load: 450 N

Item no. 50841-5-9970 · ENU · Change 94899 · Approved 2018-03-08 · Page 4 / 11

ebm-papst Mulfingen GmbH & Co. KG · Bachmühle 2 · D-74673 Mulfingen · Phone +49 (0) 7938 81-0 · Fax +49 (0) 7938 81-110 · [email protected] · www.ebmpapst.com

Содержание M3G084-DF18-81

Страница 1: ...fied trained and authorized technical staff Only authorized specialists are permitted to install the device to carry out a test run and to perform work on the electrical installation 1 3 Basic safety...

Страница 2: ...g device Long hair and dangling items of clothing jewelry and the like can become entangled and be pulled into the device Injuries can result Do not wear any loose fitting or dangling clothing or jewe...

Страница 3: ...rotective devices Following the operating instructions Improper use In particular operating the device in the following ways is prohibited and could be hazardous Conveying air that contains abrasive p...

Страница 4: ...or screw 10 mm 4 Max clearance for screw 12 mm 5 Cable PVC AWG22 3x wire end ferrule 6 Cable PVC AWG18 5x wire end ferrule 7 Groove depth 3 mm 8 Key DIN 6885 A 5 x 5 x 22 Fa Max permissible axial load...

Страница 5: ...f the device are designed for a maximum of one million load cycles If you have special questions consult ebm papst for support Use the device in accordance with its degree of protection Information on...

Страница 6: ...Requirements Check whether the information on the nameplate matches the connection data Before connecting the device make sure the power supply matches the device voltage Only use cables designed for...

Страница 7: ...es according to your application When doing so observe Chapter 4 5 Connection diagram 4 4 Factory settings Factory settings made for the device by ebm papst Mode PWM control Group address 01 Fan devic...

Страница 8: ...ing status contact break for failure 2 A max 250 VAC min 10 mA 1 6 NC white 2 Floating status contact break for failure 2 8 0 10 V yellow Control input set value 0 10 VDC impedance 100 kOhm SELV 2 10...

Страница 9: ...omatically Line undervoltage line voltage outside of permitted nominal voltage range If the line voltage returns to permitted values the motor restarts automatically 6 MAINTENANCE MALFUNCTIONS POSSIBL...

Страница 10: ...an environmental management system which is certified in accordance with ISO 14001 and rigorously implemented around the world on the basis of German standards Right from the development stage ecolog...

Страница 11: ...spose of electronic components employing the proper procedures for electronic scrap Please contact ebm papst for any other questions on disposal Item no 50841 5 9970 ENU Change 94899 Approved 2018 03...

Отзывы: