ebm-papst K4E400-AC11-13 Скачать руководство пользователя страница 5

Operating instructions

K4E400-AC11-13

Translation of the original operating instructions

3.2 Nominal data

Motor

M4E074-DF

Phase

1~

1~

Nominal voltage / VAC

230

230

Frequency / Hz

50

60

Method of obtaining
data

ml

ml

Valid for approval/
standard

-

-

Speed (rpm) / min

-1

1250

1250

Power consumption / W

205

270

Current draw / A

0.9

1.18

Capacitor / µF

6

6

Capacitor voltage / VDB

400

400

Capacitor standard

S0 (CE)

S0 (CE)

Min. ambient
temperature / °C

-25

-25

Max. ambient
temperature / °C

75

55

Starting current / A

1.4

1.3

ml = Max. load · me = Max. efficiency · fa = Free air

cs = Customer specification · ce = Customer equipment

Subject to change

3.3 Technical description

Weight

7.5 kg

Size

400 mm

Motor size

74

Rotor surface

Painted black

Impeller material

Sheet aluminum

Spacer material

Aluminum

Inlet nozzle material

Sheet aluminum

Guard grille material

Steel, galvanized

Direction of rotation

Clockwise, viewed toward rotor

Degree of protection

IP20

Insulation class

"F"

Moisture (F) /
Environmental (H)
protection class

F5

Installation position

Any

Condensation
drainage holes

None, open rotor

Mode

S1

Motor bearing

Ball bearing

Touch current
according to IEC
60990 (measuring
circuit Fig. 4, TN
system)

< 0.75 mA

Electrical hookup

Via terminals, capacitor connected

Motor protection

Thermal overload protector (TOP)
internally connected

with cable

Axial

Protection class

I (with customer connection of protective
earth)

Motor capacitor
according to EN 60252-
1 in safety protection
class

S0

Conformity with
standards

EN 60335-1

With regard to cyclic speed loads, note that the rotating parts of
the device are designed for a maximum of one million load
cycles. If you have special questions, consult ebm-papst for
support.

;

Use the device in accordance with its degree of protection.

Information on surface quality

The surfaces of the products conform to the generally applicable industrial
standard. The surface quality may change during the production period.
This has no effect on strength, dimensional stability and dimensional
accuracy.
The color pigments in the paints used perceptibly react to UV light over
the course of time. This does not however in any way affect the
technical properties of the products. The product is to be protected against
UV radiation to prevent the formation of patches and fading. Changes in
color are not a reason for complaint and are not covered by the warranty.

3.4 Mounting data

;

Secure the screws against unintentional loosening (e.g. use self-
locking screws).

For screw clearance, see Chapter 3.1 Product drawing

Strength class of
screws

8.8

Any further mounting data required can be taken from the product
drawing or Section Chapter 4.1 Mechanical connection.

3.5 Transport and storage conditions

Max. permitted
ambient temp. for
motor (transport/
storage)

+ 80 °C

Min. permitted
ambient temp. for
motor (transport/
storage)

- 40 °C

Item no. 15648-5-9970 · ENU · Change 86552 · Approved 2016-08-25 · Page 5 / 10

ebm-papst Mulfingen GmbH & Co. KG · Bachmühle 2 · D-74673 Mulfingen · Phone +49 (0) 7938 81-0 · Fax +49 (0) 7938 81-110 · [email protected] · www.ebmpapst.com

Содержание K4E400-AC11-13

Страница 1: ...qualified trained and authorized technical staff Only authorized specialists are permitted to install the device to carry out a test run and to perform work on the electrical installation 1 3 Basic sa...

Страница 2: ...n by the user NOTE Electrical or electromagnetic interference after installing the device in customer equipment Verify that the entire setup is EMC compliant 1 7 Mechanical movement DANGER Rotating de...

Страница 3: ...nt air pressure between 800 mbar and 1050 mbar Using the device within the permitted ambient temperature range see Chapter 3 5 Transport and storage conditions and Chapter 3 2 Nominal data Operating t...

Страница 4: ...duct drawing All dimensions in mm 1 3 pole connector housing Wieland 92 032 9358 1 1 1 L1 1 2 PE 1 3 N Item no 15648 5 9970 ENU Change 86552 Approved 2016 08 25 Page 4 10 ebm papst Mulfingen GmbH Co K...

Страница 5: ...in safety protection class S0 Conformity with standards EN 60335 1 With regard to cyclic speed loads note that the rotating parts of the device are designed for a maximum of one million load cycles I...

Страница 6: ...ply with multiple devices connected in parallel Electric shock risk of injury Ensure sufficient protection against accidental contact Before working on the electrical hookup short the supply and PE co...

Страница 7: ...t be checked in the application by the customer 4 3 Plug connection 4 3 1 Making supply connections Check your connector s pin assignment Connect the built in connector with the mating connector Ensur...

Страница 8: ...tructions 4 5 Connection diagram L black 1 N black 2 PE green yellow Item no 15648 5 9970 ENU Change 86552 Approved 2016 08 25 Page 8 10 ebm papst Mulfingen GmbH Co KG Bachm hle 2 D 74673 Mulfingen Ph...

Страница 9: ...t the device from the power supply at the supply line s main switch When disconnecting be sure to disconnect the ground connection last 5 MAINTENANCE MALFUNCTIONS POSSIBLE CAUSES AND REMEDIES Do not p...

Страница 10: ...requirements Always observe the applicable country specific legal regulations with regard to the disposal of products or waste occurring in the various phases of the life cycle The corresponding disp...

Отзывы: