3.2 Nominal data
Motor
M3G150-IF
Phase
3~
Nominal voltage / VAC
200
Nominal voltage
range / VAC
200 .. 240
Frequency / Hz
50/60
Type of data definition
ml
Speed / min
-1
1510
Power input / W
2900
Current draw / A
9.2
Min. ambient
temperature / °C
-25
Max. ambient
temperature / °C
45
ml = max. load · me = max. efficiency · fa = running at free air
cs = customer specs · cu = customer unit
Subject to alterations
3.3 Technical features
Mass
43 kg
Size
560 mm
Surface of rotor
Coated in black
Material of electronics
housing
Die-cast aluminium
Material of impeller
Aluminium sheet
Material of mounting
plate
Sheet steel, hot-dip galvanised
Material of distancing
profiles
Aluminium
Material of inlet nozzle
Sheet steel, hot-dip galvanised
Number of blades
9
Direction of rotation
Clockwise, seen on rotor
Type of protection
IP 54
Insulation class
"F"
Humidity class
F4-1
Mounting position
Shaft horizontal or rotor on bottom; rotor
on top on request
Condensate discharge
holes
Rotor-side
Operation mode
S1
Motor bearing
Ball bearing
Technical features
- PFC, passive
- Control input 0-10 VDC / PWM
- Over-temperature protected
electronics / motor
- Alarm relay
- Integrated PID controller
- Input for sensor 0-10 V or 4-20 mA
- Output for slave 0-10 V
- RS485 ebmBUS
- Motor current limit
- Soft start
- Line undervoltage / phase failure
detection
- Output 10 VDC, max. 10 mA
- Output 20 VDC, max. 50 mA
Touch current acc.
IEC 60990 (measuring
network Fig. 4, TN
system)
<= 3.5 mA
Electrical leads
Via terminal box
Motor protection
Reverse polarity and locked-rotor
protection
Protection class
I (if protective earth is connected by
customer)
Product conforming
to standard
EN 61800-5-1; CE
Approval
GOST; UL 2111; CSA C22.2 Nr.77
For cyclic speed loads, note that the rotating parts of the device
are designed for maximum one million load cycles. If you have
specific questions, contact ebm-papst for support.
3.4 Mounting data
;
Secure the mounting screws against accidentally coming loose (e.g.
by using self-locking screws).
Strength class for
mounting screws
8.8
You can obtain additional mounting data from the product drawing if
necessary.
3.5 Transport and storage conditions
;
Use the device in accordance with its protection type.
Max. permissible
ambient motor temp.
(transp./ storage)
+80 °C
Min. permissible
ambient motor temp.
(transp./storage)
-40 °C
3.6 Electromagnetic compatibility
If several devices are switched in parallel on the mains side so
that the line current of the arrangement is in the range of 16 - 75
A, then this arrangement conforms to IEC 61000-3-12 provided
that the short-circuit power S
sc
at the connection point of the
customer system to the public power system is greater than or
equal to 120 times the rated output of the arrangement.
It is the responsibility of the installation engineer or operator/
owner of the device to ensure, if necessary after consultation
with the network operator, that this device is only connected to
a connection point with a S
sc
value that is greater than or equal
to 120 times the rated output of the arrangement.
Item no. 50418-5-9970 · Revision 68161 · Release 2010-08-05 · Page 5 / 12
ebm-papst Mulfingen GmbH & Co. KG · Bachmühle 2 · D-74673 Mulfingen · Phone +49 (0) 7938 81-0 · Fax +49 (0) 7938 81-110 · [email protected] · www.ebmpapst.com