background image

Operating instructions

K3G280-RU26-81

Translation of the original operating instructions

3.2 Nominal data

Motor

M3G084-CF

Nominal voltage / VDC

26

Nominal voltage
range / VDC

16 .. 32

Method of obtaining
data

fa

Speed (rpm) / min

-1

2350

Power consumption / W

252

Current draw / A

10.5

Min. ambient
temperature / °C

-40

Max. ambient
temperature / °C

70

ml = Max. load · me = Max. efficiency · fa = Free air

cs = Customer specification · ce = Customer equipment

Subject to change

3.3 Data according to Commission Regulation (EU) 327/
2011

Actual

Req. 2015

01 Overall efficiency η

es

/ %

66.3

46.2

02 Measurement category

A

03 Efficiency category

Static

04 Efficiency grade N

82.1

62

05 Variable speed drive

Yes

06 Year of manufacture

The year of manufacture is specified on the
product's rating label.

07 Manufacturer

ebm-papst Mulfingen GmbH & Co. KG
Amtsgericht (court of registration) Stuttgart ·
HRA 590344
D-74673 Mulfingen

08 Type

K3G280-RU26-81

09 Power consumption P

e

/ kW

0.31

09 Air flow q

v

/ m³/h

1600

09 Pressure increase total p

fs

/

Pa

415

10 Speed (rpm) n / min

-1

2265

11 Specific ratio

*

1.00

12 Recycling/disposal

Information on recycling and disposal is
provided in the operating instructions.

13 Maintenance

Information on installation, operation and
maintenance is provided in the operating
instructions.

14 Additional components

Components used to calculate the energy
efficiency that are not apparent from the
measurement category are detailed in the
CE declaration.

*

Specific ratio = 1 + p

fs

/ 100 000 Pa

Data obtained at optimum efficiency level. The efficiency values displayed for achieving

conformity with the Ecodesign Regulation EU 327/2011 has been reached with defined air

duct components (e.g. inlet rings). The dimensions must be requested from ebm-papst. If

other air conduction geometries are used on the installation side, the ebm-papst evaluation

loses its validity/the conformity must be confirmed again. The product does not fall within

the scope of Regulation (EU) 2019/1781 due to the exception specified in Article 2 (2a)

(motors completely integrated into a product).

3.4 Technical description

Weight

8.78 kg

Size

280 mm

Motor size

84

Rotor surface

Painted black

Electronics housing
material

Die-cast aluminum

Impeller material

PA plastic, sheet-metal plate painted black

Spacer material

Aluminum

Inlet nozzle material

Sheet steel, galvanized

Support structure
material

Aluminum

Number of blades

6

Direction of rotation

Clockwise, viewed toward rotor

Degree of protection

Motor IP24 KM, electronics IP6K9K
(mating connector installed)

Insulation class

"B"

Moisture (F) /
Environmental (H)
protection class

H3

Installation position

Shaft horizontal or rotor on bottom; rotor
on top on request

Cooling hole/opening

On rotor side

Mode

S1

Motor bearing

Ball bearing

Technical features

- Lowering input
- Error output (high-side switch)
- INVLIN (inverse linear control input)
- Power limiter
- Load dump (58 V)
- Motor current limitation
- Soft start
- Control input 0-10 VDC / PWM
- Temperature derating
- Overvoltage detection
- Thermal overload protection for
electronics
- Line undervoltage detection
- Reverse polarity protection

with cable

Lateral

Protection class
assignment

III; Requires supply with safety extra-
low voltage SELV.
This component for installation may
have several local protection classes.
This information relates to this
component’s basic design.
The final protection class is based on
the component’s intended installation and
connection.

Conformity with
standards

EN 15085-1, CPC3; EN 45545-2, HL3;
EN 50155; EN 61373, Cat. 1B

Approval

EAC

;

Use the device in accordance with its degree of protection.

Item no. 56775-5-9970 · ENU · Change 265422 · Approved 2022-08-19 · Page 6 / 12

ebm-papst Mulfingen GmbH & Co. KG · Bachmühle 2 · D-74673 Mulfingen · Phone +49 (0) 7938 81-0 · Fax +49 (0) 7938 81-110 · [email protected] · www.ebmpapst.com

Содержание K3G280-RU26-81

Страница 1: ...d by suitably qualified trained and authorized technical staff Only authorized specialists are permitted to install the device to carry out a test run and to perform work on the electrical installatio...

Страница 2: ...he system machine wait until all parts have come to a standstill WARNING Rotating device Long hair and dangling items of clothing jewelry and the like can become entangled and be pulled into the devic...

Страница 3: ...he device in the following ways is prohibited and could be hazardous Operating the device in an unbalanced state e g due to dirt deposits or ice formation Resonant operation operation with severe vibr...

Страница 4: ...g All dimensions in mm 1 Cable halogen free railway application EN 45545 2x 2 5 mm 4x 1 0 mm 6x wire end ferrule Item no 56775 5 9970 ENU Change 265422 Approved 2022 08 19 Page 4 12 ebm papst Mulfinge...

Страница 5: ...ng instructions 3 1 1 Mounting dimensions All dimensions in mm Item no 56775 5 9970 ENU Change 265422 Approved 2022 08 19 Page 5 12 ebm papst Mulfingen GmbH Co KG Bachm hle 2 D 74673 Mulfingen Phone 4...

Страница 6: ...on side the ebm papst evaluation loses its validity the conformity must be confirmed again The product does not fall within the scope of Regulation EU 2019 1781 due to the exception specified in Artic...

Страница 7: ...on Bearing damage shorter service life The fan must not be subjected to force or excessive vibration from sections of the installation It is advisable to use spring or rubber isolators for decoupling...

Страница 8: ...protective earth must have a cross section equal to or greater than that of the phase conductor We recommend the use of 105 C cables Ensure that the minimum cable cross section is at least AWG 26 0 1...

Страница 9: ...4 V value of PWM signal is halved 4 0 10 V PWM yellow Control input Ri 47 k 0 10 V typ 1 V n 0 1 5 V n min 10 V n max PWM amplitude 10 V 1 50 kHz typ 5 n 0 15 n min 100 n max 5 DIAG white Diagnostic...

Страница 10: ...d remedies 4 7 Switching off the device Switching off the device during operation Switch off the device via the control input Do not switch the motor e g in cyclic operation on and off via power suppl...

Страница 11: ...hs Fasten Insulation of cables for damage Visual inspection At least every 6 months Replace cables Impeller for wear deposits corrosion and damage Visual inspection At least every 6 months Clean impel...

Страница 12: ...insulating materials on the product in cables and wires are made of similar materials and are therefore to be treated in the same manner The materials concerned are as follows Miscellaneous insulator...

Отзывы: