ebm-papst K3G250-RO44-20 Скачать руководство пользователя страница 5

Operating instructions

K3G250-RO44-20

Translation of the original operating instructions

3.2 Nominal data

Motor

M3G084-DF

Phase

1~

Nominal voltage / VAC

230

Nominal voltage
range / VAC

200 .. 277

Frequency / Hz

50/60

Method of obtaining
data

ml

Speed (rpm) / min

-1

3100

Power consumption / W

310

Current draw / A

1.6
@ 200 V

Min. ambient
temperature / °C

-25

Max. ambient
temperature / °C

40

ml = Max. load · me = Max. efficiency · fa = Free air

cs = Customer specification · ce = Customer equipment

Subject to change

3.3 Data according to Commission Regulation (EU) 327/
2011

Actual

Req. 2015

01 Overall efficiency η

es

/ %

53.8

46.2

02 Measurement category

A

03 Efficiency category

Static

04 Efficiency grade N

69.6

62

05 Variable speed drive

Yes

06 Year of manufacture

The year of manufacture is specified on the
product's rating label.

07 Manufacturer

ebm-papst Mulfingen GmbH & Co. KG
Amtsgericht (court of registration) Stuttgart ·
HRA 590344
D-74673 Mulfingen

08 Type

K3G250-RO44-20

09 Power consumption P

ed

/ kW

0.31

09 Air flow q

v

/ m³/h

1005

09 Pressure increase total p

sf

/

Pa

533

10 Speed (rpm) n / min

-1

3135

11 Specific ratio

*

1.01

12 Recycling/disposal

Information on recycling and disposal is
provided in the operating instructions.

13 Maintenance

Information on installation, operation and
maintenance is provided in the operating
instructions.

14 Additional components

Components used to calculate the energy
efficiency that are not apparent from the
measurement category are detailed in the
CE declaration.

*

Specific ratio = 1 + p

fs

/ 100 000 Pa

Data obtained at optimum efficiency level. The ErP data is determined using a motor-impeller

combination in a standardized measurement setup.

3.4 Technical description

Size

250 mm

Motor size

84

Rotor surface

Painted black

Electronics housing
material

Die-cast aluminum

Impeller material

PA66 UL plastic, sheet-metal plate
painted black

Support plate material

Sheet aluminum

Spacer material

Aluminum

Inlet nozzle material

Sheet aluminum

Guard grille material

Steel, coated with white-aluminum plastic
(RAL 9006)

Number of blades

7

Direction of rotation

Clockwise, viewed toward rotor

Degree of protection

IP20

Insulation class

"B"

Moisture (F) /
Environmental (H)
protection class

H0 - dry environment

Installation position

Shaft horizontal or rotor on top; rotor on
bottom on request

Condensation
drainage holes

None

Mode

S1

Motor bearing

Ball bearing

Technical features

- Operation and alarm display with LED
- Integrated PID controller
- Motor current limitation
- PFC, active
- RS485 MODBUS-RTU with DCI
function
- Soft start
- Control interface with SELV potential
safely disconnected from the mains
- Thermal overload protection for
electronics/motor
- Line undervoltage / phase failure
detection

Touch current
according to IEC
60990 (measuring
circuit Fig. 4, TN
system)

<= 3.5 mA

Electrical hookup

Plug

Motor protection

Thermal overload protector (TOP)
internally connected

with cable

Variable

Protection class

I (with customer connection of protective
earth)

Conformity with
standards

EN 61800-5-1; CE

Approval

CSA C22.2 No. 113; EAC; UL 507

Item no. 58126-5-9970 · ENU · Change 224212 · Approved 2021-02-11 · Page 5 / 11

ebm-papst Mulfingen GmbH & Co. KG · Bachmühle 2 · D-74673 Mulfingen · Phone +49 (0) 7938 81-0 · Fax +49 (0) 7938 81-110 · [email protected] · www.ebmpapst.com

Содержание K3G250-RO44-20

Страница 1: ...authorized specialists are permitted to install the device to carry out a test run and to perform work on the electrical installation 1 3 Basic safety rules 1 1 3 Basic safety rules The safety hazard...

Страница 2: ...y that the entire setup is EMC compliant 1 7 Mechanical movement DANGER Rotating device Risk of injury to body parts coming into contact with the rotor or the impeller Secure the device against accide...

Страница 3: ...prohibited and could be hazardous Operating the device in an unbalanced state e g due to dirt deposits or ice formation Resonant operation operation with severe vibration This also includes vibration...

Страница 4: ...9058 1 2 1 L 2 2 PE 2 3 N 3 8 pole connector housing TE 100616 2 4 8 pole connector housing TE 100616 2 5 Switch ARCOLECTRIC SWITCHES P L C no H8550VBACF As delivered condition end customer switch se...

Страница 5: ...t optimum efficiency level The ErP data is determined using a motor impeller combination in a standardized measurement setup 3 4 Technical description Size 250 mm Motor size 84 Rotor surface Painted b...

Страница 6: ...resistant safety gloves NOTE Damage to the device from vibration Bearing damage shorter service life The fan must not be subjected to force or excessive vibration from sections of the installation If...

Страница 7: ...on The values are typically in the range 250 mA At the same time the effective power in this operating state operational readiness is typically 4 W 4 2 3 Residual current circuit breaker RCCB If the...

Страница 8: ...US RSA KL2 KL3 2 RSB RS 485 interface for MODBUS RSB KL2 KL3 3 RSA RS 485 interface for MODBUS RSA KL2 KL3 4 Bridge KL2 KL3 KL2 KL3 5 Bridge KL2 KL3 KL2 KL3 6 RSB RS 485 interface for MODBUS RSB KL2 K...

Страница 9: ...ons cause the motor to switch off automatically in the event of the faults described in the table Fault Safety feature description function Rotor position detection error An automatic restart follows...

Страница 10: ...will shorten the service life of the fan Severe vibration can destroy the fan In such cases switch off the fan immediately and clean it The preferred method of cleaning is dry cleaning e g using comp...

Страница 11: ...lified personnel with the appropriate technical knowledge The product is to be disassembled into suitable components for disposal employing standard procedures for motors WARNING Heavy parts of the pr...

Отзывы: